Yamaha RM1x Service Manual page 36

Yamaha rm1x sequence remixer service manual
Hide thumbs Also See for RM1x:
Table of Contents

Advertisement

RM1x
SOUND CONTROLLER 6 adjusts the envelope decay time specified by the Voice. This is a relative
parameter, and specifies an increase or decrease centered at 64.
BRIGHTNESS adjusts the cutoff frequency specified by the Voice. This is a relative parameter, and
specifies an increase or decrease centered at 64. Decreasing the value will make the sound more
mellow. For some voices, the effective range may be less than the range of the setting.
SOUND CONTROLLER 7 adjusts the LFO Frequency specified by the Voice. This is a relative
parameter, and specifies an increase or decrease centered at 64.
(3-2) CHANNEL MODE MESSAGES
STATUS
1011nnnn(BnH)
CONTROL NUMBER
0ccccccc
CONTROL VALUE
0vvvvvvv
(3-2-1) ALL SOUND OFF
Turns off the sound of all currently sounding notes on the corresponding channel. The status of
channel messages such as Note On and Hold On is also turned off.
(3-2-2) RESET ALL CONTROLLERS (CONTROL NUMBER = 79H , DATA VALUE = 0)
Resets the values of the following controllers.
PITCH BEND CHANGE
MODULATION
AC1 CONTROLLER
EXPRESSION
SUSTAIN SWITCH
PORTAMENTO SWITCH
SOSTENUTO SWITCH
SOFT PEDAL
NRPN
RPN
PORTAMENT CONTROL
The following data will not change.
PROGRAM CHANGE, BANK SELECT MSB/LSB, VOLUME, PAN, HARMONIC CONTENT,
RELEASE TIME, ATTACK TIME, BRIGHTNESS, SOUND CONTROLLER 6,SOUND
CONTROLLER 7, DRY SEND LEVEL,EFFECT SEND LEVEL 1, EFFECT SEND LEVEL 3,EFFECT
SEND LEVEL 4,PITCH BEND SENSITIBITY, FINE TUNING, COURSE TUNING
(3-2-3) ALL NOTE OFF (CONTROL NUMBER = 7BH , DATA VALUE = 0)
Turns off all notes of the corresponding channel which are on. However if Sustain or Sostenuto are on,
the sound will continue until these are turned off.
(3-2-4) OMNI MODE OFF (CONTROL NUMBER = 7CH , DATA VALUE = 0)
Performs the same processing as when ALL NOTE OFF is received. Sets the VOICE RECEIVE
CHANNEL to OMNI OFF and CHANNEL = 1.
(3-2-5) OMNI MODE ON (CONTROL NUMBER = 7DH , DATA VALUE = 0)
Performs the same processing as when ALL NOTE OFF is received. Does not set OMNI ON. Sets the
VOICE RECEIVE CHANNEL to OMNI ON.
(3-2-6) MONO (CONTROL NUMBER = 7EH , DATA VALUE = 0)
Performs the same processing as when All SOUND OFF is received, and if the 3rd byte (mono
number) is in the range 0 - 16, sets the corresponding channel to Mode 4 (m=1). If in the VOICE
MODE, Mode 2 (m=1) is also possible, according to the VOICE RECEIVE CHANNEL.
(3-2-7) POLY (CONTROL NUMBER = 7FH , DATA VALUE = 0)
Performs the same processing as when ALL SOUND OFF is received, and sets the corresponding
channel to Mode 3. When in the VOICE MODE, Mode 1 is also possible, according to the VOICE
RECEIVE CHANNEL.
(3-3) REGISTERED PARAMETER NUMBER
STATUS
1011nnnn(BnH)
LSB
01100100(64H)
RPN LSB
0ppppppp
MSB
01100101(65H)
RPN MSB
0qqqqqqq
DATA ENTRY MSB
00000110(06H)
DATA VALUE
0mmmmmmm
DATA ENTRY LSB
00100110(26H)
DATA VALUE
0lllllll
First transmit an RPN MSB and RPN LSB to specify the parameter that is to be controlled, then use
Data Entry to set the value of the specified parameter.
RPN
D.ENTRY
LSB MSB
MSB LSB
PARAMETER NAME
00H 00H
mmH ---
PITCH BEND SENSITIVITY
01H 00H
mmH llH
MASTER FINE TUNE
02H 00H
mmH ---
MASTER COARSE TUNE
7FH 7FH
--- ---
RPN RESET
(3-4) NON-REGISTERED PARAMETER NUMBER
STATUS
1011nnnn(BnH)
LSB
01100010(62H)
RPN LSB
0ppppppp
MSB
01100011(63H)
RPN MSB
0qqqqqqq
DATA ENTRY MSB 00000110(06H)
DATA VALUE
0mmmmmmm
First transmit an NRPN MSB and NRPN LSB to specify the parameter that is to be controlled, then
use Data Entry to set the value of the specified parameter.
NRPN
D.ENTRY
MSB LSB
MSB LSB
PARAMETER NAME
01H 08H
mmH ---
VIBRATO RATE
01H 09H
mmH ---
VIBRATO DEPTH
01H 0AH
mmH ---
VIBRATO DELAY
01H 20H
mmH ---
FILTER CUTOFF FREQUENCY 00H - 40H - 7FH (-64 - 0 - +63)
01H 21H
mmH ---
FILTER RESONANCE
01H 63H
mmH ---
EG ATTACK TIME
01H 64H
mmH ---
EG DECAY TIME
01H 66H
mmH ---
EG RELEASE TIME
50
n = 0 ~ 15 VOICE CHANNEL NUMBER
c = CONTROL NUMBER
v = DATA VALUE
(CONTROL NUMBER = 78H , DATA VALUE = 0)
0 (center)
0 (off)
0 (minimum)
127 (maximum)
0 (off)
0 (of f)
0 (off)
0 (off)
Un-set status. Internal data will not change.
Un-set status. Internal data will not change.
reset
n = 0 - 15 VOICE CHANNEL NUMBER
p = RPN LSB (Refer to the table on the following page.)
q = RPN MSB (Refer to the table on the following page.)
m = Data Value
l = Data Value
DATA RANGE
00H - 18H (0 - 24 semitones)
{mmH,llH} = {00H,00H} - {40H,00H} - {7FH,7FH}
(-8192*100/8192) - 0 - (+8192*100/8192)
28H - 40H - 58H (-24 - 0 - +24 semitones)
Set to a condition in which the RPN number is unspecified.
Internal settings will not change.
n = 0 - 15 VOICE CHANNEL NUMBER
p = NRPN LSB (Refer to the table on the following page.)
q = NRPN MSB (Refer to the table on the following page.)
m = Data Value
DATA RANGE
00H - 40H - 7FH (-64 - 0 - +63)
00H - 40H - 7FH (-64 - 0 - +63)
00H - 40H - 7FH (-64 - 0 - +63)
00H - 40H - 7FH (-64 - 0 - +63)
00H - 40H - 7FH (-64 - 0 - +63)
00H - 40H - 7FH (-64 - 0 - +63)
00H - 40H - 7FH (-64 - 0 - +63)
(3-5) SYSTEM REAL TIME MESSAGES
(3-5-1) ACTIVE SENSING
STATUS
11111110
(FEH)
Transmitted at intervals of approximately 200 msec.
Not transmitted during disk read/write operations.
Once this message is received, SENSING will begin. If neither STATUS nor DATA messages are
received for an interval longer than approximately 350 msec, the MIDI RECEIVE BUFFER will be
cleared, and all sounding notes and SUSTAIN SWITCH will be forced off. Also, data for each of the
controls will be reset to specific values.
(3-6) SYSTEM EXCLUSIVE MESSAGE
(3-6-1)UNIVERSAL NON REALTIME MESSAGE
(3-6-1-1)GENERAL MIDI MODE ON
F0H 7EH 7FH 09H 01H F7H
The following controller values will be reset.
VOLUME
PAN
PROGRAM CHANGE
BANK SELECT MSB
REVERB DEPTH
PITCH BEND CHANGE
MODULATION
EXPRESSION
SUSTAIN SWITCH
SOSTENUTO SWITCH
RPN
PORTAMENT CONTROL
MIDI MASTER VOLUME
PITCH BEND SENSITIBITY
FINE TUNING
COURSE TUNING
(3-6-1-2)IDENTITY REQUEST (Received only)
F0H 7EH 0nH 06H 01H F7H ("n" is the device number, but the RM1x receives this in
Omni.)
(3-6-1-3)IDENTITY REPLY (Transmitted only)
F0H 7EH 7FH 06H 02H 43H 00H 41H ddH ddH 00H 00H 00H 01H F7H
dd;Device Number Code
(3-6-2)UNIVERSAL REALTIME MESSAGE
(3-6-2-1) MIDI MASTER VOLUME
F0H 7FH 7FH 04H 01H llH mmH F7H
Modifies the MASTER VOLUME value.
The value of mm is used as the MIDI Master Volume (the ll value is ignored).
(3-6-3)PARAMETER CHANGE
(3-6-3-1) MIDI MASTER TUNING
F0H 43H 1nH 27H 30H 00H 00H mmH llH ccH F7H
Modifies the MASTER TUNE value.
The values of mm and ll are used as the MIDI Master Tuning.(n and cc values are
ignored.)
T = M*200/256-100
Where
T : actual tuning value (-99 - +99)
M: a one-byte value with MSB of "mm" bits 0-3, and LSB of
"ll" bits 0-3.
(3-6-3-2) XG SYSTEM ON
11110000
F0
Exclusive status
01000011
43
YAMAHA ID
0001nnnn
1n
device Number
01001100
4C
Model ID
0aaaaaaa
00
Address High
0aaaaaaa
00
Address Mid
0aaaaaaa
7E
Address Low
00000000
00
Data
11110111
F7
End of Exclusive
When ON is received, controllers will be reset and all Multi Part and Effect data of the
attached table will be reset to the XG default values.
(3-6-3-3) XG PARMETER CHANGE
11110000
F0
01000011
43
0001nnnn
1n
01001100
4C
0aaaaaaa
aaaaaaa
0aaaaaaa
aaaaaaa
0aaaaaaa
aaaaaaa
0ddddddd
ddddddd
|
11110111
F7
For parameters with a Data Size of 2 or 4, the corresponding amount of data will be
transmitted.
For Addresses and Byte Counts, refer to the attached tables.
The following 3 types are received.
System Data
Multi Effect Data
Multi Part Data
100
Center
1 (Grandpno)
0
4
0 (center)
0 (off)
127 (maximum)
0 (off)
0 (off)
Un-set status.
reset
127 (maximum)
02 (2 semitones)
0
0
RM1x = 1DH,03H
Exclusive status
YAMAHA ID
device Number
Model ID
Address High
Address Mid
Address Low
Data
|
End of Exclusive

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents