GB
3.2
TECHNICAL DATA: LKB 320
Standard delivery:
Power source equipped with switch for 2/4 step trigger action with gas pre--flow and
gas post--flow in the 4 step mode and adjustable burnback time.
Integrated wire feed mechanism with feed roller for solid wire, diameter 1.0, and 1.2.
Welding torch PSF 315 4.5 m.
Return cable 4.5 m with return clamps.
Mains cable 5 m and gas hose.
Includes: Handle, (fitted with 2 screws,) gas cylinder shelf (fitted with 2 screws).
Voltage
Permissible load at
100% duty cycle
60 % duty cycle
30 % duty cycle
Setting range (DC)
Open circuit voltage
Open circuit power
Efficiency
Power factor
Control voltage
Dimensions lxwxh
Weight
Enclosure class
Application classification
LKB 320 comply with the requirements of IEC 974- - 1.
The IP code indicates the enclosure class, i.e. the degree of protection against pene-
tration by solid objects and water.
Equipment marked IP 23 is designed for in-- and outdoor use.
The symbol
indicates that the power source is designed for use in areas where
there is an increased electrical hazard.
bc14d12e
400- - 415 V, 3 50 Hz
195 A/24 V
250 A/27 V
320 A/30 V
40A/16(14)V--320A/30V
16--40 V
52 W
0.71
0.97
42 V, 50/60 Hz
770x520x620
112 kg
IP 23
- - 38 - -
230/400- -415/500V350Hz
230/440- -460V, 360Hz
195 A/24 V
250 A/27 V
320 A/30 V
40A/16(14)V--320A/30V
16--40 V
52 W
0.71
0.97
42 V, 50/60 Hz
770x520x620
112 kg
IP 23
Need help?
Do you have a question about the LKB 265 and is the answer not in the manual?
Questions and answers