Use the diagrams in the manual when tracing faults. The machine components are described in alphabetical order on the pages foregoing the connection diagram. The LKA 180 and 240 are designed and tested in accordance with international standard EN 60974−1, EN 50199.
RATING PLATE The rating plate is secured to the back of the machine. The example shown below is the rating plate for an LKA 240 with an explanation of how the plate should be read and interpreted. 1. LKA 240 is the type designation for this power source. The first letter, L, indicates that the LKA 240 is a rectifier, while K indicates Compact (Kompakt in Swedish) and A indi- cates the design generation.
Page 5
341 indicates Week 41, 1993. The final group (zzz) consists of three or four figures, and is a serial number in the range 0001 to 9999. 7. Shows that ESAB complies with the international standard, IEC 974− 1. − 3 − clka1de1...
Switch, 7−way in the LKA 180 and 10−way in the LKA 240. Resistor, 1 Ω, only fitted in the single−phase version of LKA 180. Resistor, 5.6 kΩ 5 W, only fitted in the single−phase version of LKA 180. Welding torch trigger switch Thermal overload cutout, for protection against overload, fitted in the winding of main transformer TM1.
CONNECTION DIAGRAM, LKA 180 Single−phase, 230 V The first 150 machines were delivered with switch 0408/8112. The part No. in the spare parts list is referring to the other switch, which has to be used as spare part for all machines.
CONNECTION DIAGRAM, LKA 180 3−phase, 400 V When checking the no−load voltages, load the machine with a dummy load of 5.6 kΩ 5 W, connecting it between plus and minus on the rectifier bridge. clka1e01 − 6 − clka1de1...
CONNECTION DIAGRAM, LKA 180 3−phase, 230/400 V When checking the no−load voltages, load the machine with a dummy load of 5.6 kΩ 5 W, connecting it between plus and minus on the rectifier bridge. clka1e12 − 7 − clka1de1...
CONNECTION DIAGRAM, LKA 240 3−phase, 400 V When checking the no−load voltages, load the machine with a dummy load of 5.6 kΩ 5 W, connecting it between plus and minus on the rectifier bridge. clka1e02 − 8 − clka1de1...
CONNECTION DIAGRAM, LKA 240 3−phase, 230/400 V When checking the no−load voltages, load the machine with a dummy load of 5.6 kΩ 5 W, connecting it between plus and minus on the rectifier bridge. clka1e13 − 9 − clka1de1...
The rectified voltage is about 24 V in the fan−cooled machines and somewhat higher in the 3−phase LKA 180. This supply powers fan EV1 in the fan−cooled machines. Voltage regulator VR1 is supplied via diode D1 to provide a regulated 15 "0.6 V supply.
Page 16
START/STOP CIRCUIT, THERMAL OVERLOAD CIRCUIT AND SPOT WELDING CIRCUIT clka1e08 START AND STOP CIRCUIT When the torch trigger switch SB1 is not activated, the voltage between M3 and M4 is 24 V. Pressing the trigger switch shorts the circuit, producing a voltage of 0 V between M3 and M4.
Page 17
BURN−BACK TIME clka1e09 The burn−back time is the time from when wire feed ceases until contactor KM1 drops off. During welding, the voltage at pin 13 of IC2 is low. The output of the inverter at pin 14 is therefore high, turning on transistor Q2 and activating relay RE1. When the torch trigger switch is released, or when the spot welding time expires, capacitor C23 charges up via resistors R36, R37 and R38.
Page 18
MOTOR DRIVE AND BRAKING clka1e10 MOTOR DRIVE CIRCUIT The output stage of the pulse width modulator is connected to transistor Q1 via resistor R16. A motor current signal is provided by measuring the voltage across resistor R4, connected to transistor Q1. If the voltage across R4 exceeds 1.1 V "60 mV, the gate pulses to Q1 are inhibited.
IP21 indicates the enclosure class in respect of protection against penetrating objects and water. Enclosure class IP21 indicates that the equipment is intended for indoor use, while IP23 equipment is also suitable for outdoor use. Main dimensions, LKA 180 and LKA 240 clka1p08 − 18 −...
INSTALLATION Place the machine in a suitable position and check that cooling is not obstructed. Check that the machine is connected to suit the mains supply voltage. In the machines that can be connected for different supply voltages, make the appropriate connections as required at terminal block XT3 and transformer TC1.
GASLESS WIRE SOLID WIRE clka0p10 When welding with gasless wire, the return current cable must be connected to the positive terminal on the terminal block above the wire feed unit. OPERATION Connect the return current conductor clamp (E) to the workpiece. When welding with solid wire, open the gas valve (A) on the gas bottle and adjust the gas flow by reducer valve (B).
Do not tension the pressure roller too hard, as this will result in abnormal wear to the pressure roller, the feed roller and the wire guide. Welding torch. Blow the wire guide clean and clean the gas nozzle at regular intervals. WELDING DATA SELECTION MACHINE SETTINGS, LKA 180 single−phase clka1p15 − 21 − clka1de1...
Spare parts list - Reservdelsförteckning - Ersatzteilverzeichnis - Liste de pièces détachées Spare parts are to be ordered through the nearest ESAB agency as per the list on the back of the cover. Kindly indicate type of unit, serial number, denominations and ordering numbers according to the spare parts list.