Advertisement

Quick Links

User Manual

Netbiter
EasyConnect Gateway
®
Doc: HMSI-168-92
Rev: 3.10
Connecting Devices
HMS Industrial Networks
Mailing address: Box 4126, 300 04 Halmstad, Sweden
E-mail: info@hms-networks.com
Visiting address: Stationsgatan 37, Halmstad, Sweden
Web: http://netbiter.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Netbiter EasyConnect and is the answer not in the manual?

Questions and answers

Summary of Contents for HMS Netbiter EasyConnect

  • Page 1: User Manual

    User Manual Netbiter EasyConnect Gateway ® Doc: HMSI-168-92 Rev: 3.10 Connecting Devices HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden E-mail: info@hms-networks.com Visiting address: Stationsgatan 37, Halmstad, Sweden Web: http://netbiter.com...
  • Page 2: Intellectual Property Rights

    Netbiter Argos. Liability Every care has been taken in the preparation of this manual. Please inform HMS Industrial Networks AB of any inaccuracies or omissions. The data and illustrations found in this document are not binding. We, HMS Industrial Networks AB, reserve the right to modify our products in line with our policy of continuous product development.
  • Page 3: Table Of Contents

    Netbiter EC220............................19 Netbiter EC250............................20 Netbiter EC310 ............................22 Netbiter EC350 ............................24 Ethernet Link LED:s (on RJ‐45 ports)  ....................26 Wiring Examples Netbiter EC150/EC250 ..........................27 Netbiter EC220............................27 Netbiter EC310 / EC350 ........................... 29 Connecting GPS Devices ......................... 31 Activating the GPS Function ........................31 Activation Adding a Gateway to Netbiter Argos ....................32 Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 4 Adapter ..............................36 Local Configuration Ethernet Connection ..........................38 USB Connection (EC310 / EC350) ......................38 Netbiter EC150............................39 Netbiter EC250............................41 Netbiter EC310 / EC350 ........................... 44 Firmware Update Using Netbiter Update (EC150/250) ...................... 49 Technical Specifications Dimensions..............................52 Specifications EC150 & EC220........................ 57 Specifications EC250, EC310 & EC350....................58 Regulatory notices............................ 59 Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 5: About This Document

    About This Document P. About This Document P.1 Related Documents Document Author Netbiter Argos Administration Manual Netbiter EasyConnect Gateway Installation Guides Netbiter Remote Access User Manual (EC310/EC350) P.2 Document History Summary of Recent Changes (3.00... 3.10) Change Page(s) Added information about EtherNet/IP symbolic segment addressing...
  • Page 6: Conventions & Terminology

    P.3 Conventions & Terminology • Unordered (bulleted) lists are used for information such as feature lists, and for in‐ structions that can be carried out in any order. 1. Ordered lists are used for instructions that must be carried out in sequence. Bold text is used to indicate interactible named parts such as connectors and switches on  the hardware, or clickable objects in a graphical user interface. Monospaced text is used to indicate configuration file entries, program code examples, etc. This is a cross‐reference to another page in this document. This is a link to a resource on the Internet (URL). This is an important instruction which must be followed!  This is additional information that will facilitate installation and/or operation. P.4 Support For additional documentation, general information and technical support, please refer to  the contact and support pages at www.netbiter.com/support. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 7: Installation

    Installation 1. Installation 1.1 Netbiter EC150 / EC250 DIN Rail Mount Netbiter EC150 and Netbiter EC250 are supplied  ready for mounting on a DIN rail. Mounting 1. Lower the unit onto the upper lip of the rail. 2. Press the unit towards the rail. It will snap  into place on the lower lip. Removing 1. Insert a flat‐head screwdriver into the slot‐ ted tab on the bottom of the unit and pull the  tab gently downwards. 2. Pull the lower side of the unit free of the rail. 3. Lift the unit from the rail. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 8: Netbiter Ec220, Ec310 And Ec350

    Installation 1.2 Netbiter EC220, EC310 and EC350 Wall Mount The Netbiter EC220, EC310 and EC350 can be screw‐mounted directly to a flat surface us‐ ing the screw holes in the metal casing. DIN Rail Mount The Netbiter EC220, EC310 and EC350 can also be mounted on a DIN rail using an optional  rail mounting kit.  Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 9: Connections

    Tx (Transmit) DTR (Data Terminal Ready) DSR (Data Set Ready) RTS (Request To Send) CTS (Clear To Send) RI (Ring Indicator) 2.1.3 Ethernet Connector The RJ‐45 socket provides Ethernet network connection. It also supports Modbus TCP via  Ethernet, which can be used at the same time as Modbus RTU units on another interface. Function 4, 5, 7, 8 Termination Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 10: Netbiter Ec220

    -50 to +150 °C (default) Input resistance 270  0–20 mA Current Input resistance 280  0–10 VDC Voltage 1. Unscrew the two top screws (A) using a T10 torx screwdriver.  2. Loosen the two lower screws (B) but do not remove them.  3. Lift the cover carefully. Take care not to damage the antenna cable. 4. Set the switch to match the desired function for the analog input. 5. Replace the cover, again taking care not to damage the antenna cable.  6. Re‐tighten all 4 screws Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 11: Antenna Connector

    CD (Carrier Detect) Rx (Receive) Tx (Transmit) DTR (Data Terminal Ready) DSR (Data Set Ready) RTS (Request To Send) CTS (Clear To Send) RI (Ring Indicator) 2.2.4 Antenna Connector The antenna connector is a standard SMA screw connector. Optional external antennas are  available from your supplier. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 12: Sim Card

    Connections 2.2.5 SIM Card Netbiter SIM card The Netbiter SIM cards supplied by HMS are pre‐configured and ready for use and have  PIN code security disabled as default.  Other SIM cards To use any other SIM card, the following information is required: • The phone number for the SIM card • The Access Point Name (APN) to connect to  • User name and password (if required by the network operator) SIM cards with active PIN codes cannot be used in Netbiter EC220. The PIN code  cannot be disabled in the gateway or in Netbiter Argos. To disable the PIN code, put  the SIM card in a mobile phone and follow the manufacturer’s instructions.  Installing the SIM card 1. Push the yellow button next to the SIM card holder and remove the holder. 2. Place the SIM card in the holder and insert the holder into the unit as shown in the  figure. Observe the position of the cut‐off corner and the contact surfaces.  Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 13: Netbiter Ec250

    Tx (Transmit) DTR (Data Terminal Ready) DSR (Data Set Ready) RTS (Request To Send) CTS (Clear To Send) RI (Ring Indicator) 2.3.3 Ethernet Connector The RJ‐45 socket provides Ethernet network connection. It also supports Modbus TCP via  Ethernet, which can be used at the same time as Modbus RTU units on another interface. Function 4, 5, 7, 8 Termination Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 14 2.3.5 SIM Card Netbiter SIM card The Netbiter SIM cards supplied by HMS are pre‐configured and ready for use and have  PIN code security disabled as default.  Other SIM cards To use any other SIM card, the following information is required: • The phone number for the SIM card • The Access Point Name (APN) to connect to  • User name and password (if required by the network operator) SIM cards with active PIN codes cannot be used in Netbiter EC250. The PIN code  cannot be disabled in the gateway or in Netbiter Argos. To disable the PIN code, put  the SIM card in a mobile phone and follow the manufacturer’s instructions.  Installing the SIM card 1. Push the yellow button next to the SIM card holder and remove the holder. 2. Place the SIM card in the holder and insert the holder into the unit as shown in the  figure. Observe the position of the cut‐off corner and the contact surfaces.  Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 15: Netbiter Ec310 / Ec350

    The relay output must be supplied from an isolating transformer using a secondary listed fuse rated at maximum 3.3 A and minimum 30 VDC. Digital Inputs Netbiter EC310/350 features 2 digital inputs of the dry contact type which do not require  any control voltage and will function with a switch or breaker.  The digital inputs on EC310/350 are of the “dry contact” type which do not require  any control voltage and will function with a switch or breaker. Do not connect a  power source to the digital inputs, as this may damage the unit.    Maximum recommended cable length for the digital inputs is 3 m.  2.4.2 Power connector Function 12–48 VDC Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 16 Rx Tx GND Function Rx Receive input Tx Transmit output Signal ground 2.4.5 Ethernet Connectors (RJ-45) WAN:  For connecting to the Internet and Netbiter Argos.  LAN:  For EtherNet/IP, Modbus TCP, and Remote Access. Link activity indicators Protective Earth GPS antenna connector (Netbiter EC350 only) Do not connect the LAN and WAN ports to the same physical network. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 17 The USB connector can be used to connect locally to the Netbiter EC310/350 for firmware  upgrades, configuration or troubleshooting.  See also “Local Configuration” on page 38.  USB connector 2.4.7 3G/GPRS Antenna Connector (Netbiter EC350 only) The 3G/GPRS antenna connector on the front of the unit is a standard female SMA screw  connector. A stub antenna is supplied as standard, and optional external antennas are  available from your supplier. 2G/3G antenna connector GPS antenna connector 2.4.8 GPS Antenna Connector (Netbiter EC350 only) The Netbiter EC350 has a built‐in GPS receiver. An external GPS antenna (not included)  should be connected to the female SMA screw connector on the underside of the unit. The  connector also provides power for active GPS antennas.  Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 18 2.4.9 SIM Card (Netbiter EC350 only) Netbiter SIM card The EC350 will automatically detect a Netbiter SIM card and apply the correct APN set‐ tings for connection with Netbiter Argos. No further SIM card configuration is needed. Other SIM cards To use any other SIM card, the following information is required: • The phone number for the SIM card • The Access Point Name (APN) to connect to  • User name and password (if required by the network operator) SIM cards with active PIN codes cannot be used in Netbiter EC350. The PIN code  cannot be disabled in the gateway or in Netbiter Argos. To disable the PIN code, put  the SIM card in a mobile phone and follow the manufacturer’s instructions.  Installing a SIM card 1. Insert the SIM card carefully into the EC350 as shown in the figure.  Observe the position of the cut‐off corner and the contact surfaces.  2. Push the SIM card firmly down into the holder until it clicks into place.  To remove the SIM card, press the edge of the card and relase it.  When inserting the SIM card, make sure that it does not accidentally slip behind the  SIM card holder.  Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 19: Power

    Connections 2.5 Power Make sure that the power supply is correctly connected. Connecting with reverse po‐ larity or using the wrong type of power supply may damage the unit. Netbiter EC150 and EC250 Connect 9–24 VDC to Vin+ (EC150) or V+ (EC250), and connect ground to GND.  Netbiter EC150 can alternatively be powered by 9–24 VAC. Netbiter EC220 Connect 9–24 VDC to +VDC, and connect ground to GND Netbiter EC310/350 Connect 12–48 VDC to + (plus), and connect ground to ‐ (minus). Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 20: Led Indicators

    Transmitting serial packet 3.1.3 Activity/Collision Indication Meaning Green (flashing) Receiving Ethernet packet Red (flashing) Ethernet collision detected 3.1.4 Link Indication Meaning Green 10 Mb/s Ethernet network detected Orange 100 Mb/s Ethernet network detected Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 21: Netbiter Ec220

    • Check that the mobile network provider grants access to port 5222. a. The Netbiter SIM card will automatically connect to a network in the global HMS “home network” group of network operators. A list of these operators can be found at the Netbiter support website, www.netbiter.com/support.
  • Page 22: Netbiter Ec250

    • Check that at least one of ports 443, 80 or 5222 are open in the firewall. a. The Netbiter SIM card will automatically connect to a network in the global HMS “home network” group of network operators. A list of these operators can be found at the Netbiter support website, www.netbiter.com/support.
  • Page 23 Unit is starting up 3.3.3 Ethernet Activity Indication Meaning Green (flashing) Receiving Ethernet packet 3.3.4 Link Indication Meaning Green (steady) 10 Mb/s Ethernet network detected Orange (steady) 100 Mb/s Ethernet network detected Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 24: Netbiter Ec310

    Firmware update in progress Red (steady) Hardware failure • Contact Netbiter support. Red (flashing) Application failure • Contact Netbiter support. 3.4.4 Power Indication Meaning No power Green (steady) Unit has power Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 25 LED Indicators 3.4.5 Ethernet Link LED:s (on RJ-45 ports) Indication Meaning No Ethernet traffic Orange (flashing) Activity on 10 Mbit/s Ethernet network Green (flashing) Activity on 100 Mbit/s Ethernet network Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 26: Netbiter Ec350

    • Check that the antenna is correctly installed and pointing upwards. • Use an external antenna. Try different antenna placements to get an optimal signal. 1 green LED (flashing) Acceptable mobile signal 2–5 green LEDs (flashing) Good to optimum mobile signal Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 27 • Check that the mobile network provider grants access to port 5222. a. The Netbiter SIM card will automatically connect to a network in the global HMS “home network” group of network operators. A list of these operators can be found at the Netbiter support website, www.netbiter.com/support.
  • Page 28: Ethernet Link Led:s (On Rj-45 Ports)

    LED Indicators 3.6 Ethernet Link LED:s (on RJ-45 ports) Indication Meaning No Ethernet traffic Orange (flashing) Activity on 10 Mbit/s Ethernet network Green (flashing) Activity on 100 Mbit/s Ethernet network Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 29: Wiring Examples

    Analog Input – 3-wire Current Sensor EC220 AI:AI 1/2 PT100 0–20 mA 0-20 mA 0-10 V AI:COM Analog Input – 4-wire Current Sensor EC220 AI:AI 1/2 PT100 0–20 mA 0-20 mA 0-10 V AI:COM Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 30 4.2.2 Output Wiring Examples Analog output EC220 Analog load 0–10 V AO:OUT Max load resistance = 2 k AO:COM Relay output EC220 Load Fuse 24 V DC/AC Relay:NO Relay:COM The relay output must be supplied from an isolating transformer using a secondary  listed fuse rated at maximum 3.3 A and minimum 30 VDC. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 31: Netbiter Ec310 / Ec350

    Analog In:AI1 (AI2/3/4) 0–20 mA Analog In:COM Analog Input – Temperature Sensor EC310 / EC350 Analog In:AI1 (AI3) PT100 Analog In:COM Digital Input EC310 / EC350 DI/Pulse In:DI1+ (DI2+) DI/Pulse In:DI1- (DI2-) Do not connect a power source to the digital inputs, as this may damage the unit.   Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 32 Wiring Examples 4.3.2 Output Wiring Example Relay Output EC310 / EC350 Load Fuse 24 V DC/AC Relay:NO Relay:COM The relay output must be supplied from an isolating transformer using a secondary  listed fuse rated at maximum 3.3 A and minimum 30 VDC. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 33: Gps

    Rx (Receive from GPS) Ground 5.1.2 Netbiter EC250 To connect a GPS device to Netbiter  EC250, a 9‐pin female D‐sub connector  is needed. Function Tx (Transmit to GPS) Rx (Receive from GPS) Ground 5.1.3 Netbiter EC350 The Netbiter EC350 has a built‐in GPS receiver. To use the GPS function, connect a suitable  GPS antenna (not included) to the unit.  5.2 Activating the GPS Function GPS functionality must be activated in Netbiter Argos before it can be used. Instructions on  how to activate the function can be found in the online documentation in Netbiter Argos.  Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 34: Activation

    Activation 6. Activation Before the Netbiter EasyConnect Gateway can be used, it must be registered and activated  in Netbiter Argos. This can be done in one of two ways: • By using the gateway to create a completely new user account in Netbiter Argos.  • By adding the gateway to an existing account in Netbiter Argos.  About Netbiter Argos Netbiter Argos is a web‐based communications centre for all your connected Netbiter  EasyConnect gateways, accessible from any Internet connected browser. It is used for acti‐ vating and configuring your Netbiter gateways and provides access to control functions,  logs and stored data.  6.1 Adding a Gateway to Netbiter Argos For more information on the installation process, please refer to the Installation Guide sup‐ plied with the gateway and to the Netbiter Argos Administration Manual.  The Netbiter Argos Administration Manual is available at www.netbiter.com/support.  Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 35: Installation On An Ethernet Network

    5222, 443, 80 (the ports are tried in the order shown) Connection attempts will be made to 3 different servers with a timeout of 30 seconds each.  This means that it may take up to 4 min 30 sec to establish a connection for EC150/220/250  (3 ports x 3 servers x 30 seconds). Other ports The following ports may also need to be opened in the firewall: • 502  Default port for Modbus TCP  • 8080  Extra web server 7.1 Network Setup - Dynamic IP Address When using DHCP (the default setting), there is no need to configure any of the IP address  related settings. The only changes that may be required are the settings needed to pass  through a proxy server on the network, see “Local Proxy Setup” on page 43. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 36: Network Setup - Fixed Ip Address

    Installation on an Ethernet Network 7.2 Network Setup - Fixed IP Address Fixed IP address settings for the Netbiter EasyConnect Gateway must be configured using  the IPconfig utility available from www.netbiter.com/support. 1. Start IPconfig and double‐click on the unit you wish to configure. (MAC = the System ID for the gateway)  2. Set DHCP to Off, then enter the IP address and the other parameters as required.  Contact your network administrator if in doubt.  3. Click the Set button to save the configuration. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 37: Ethernet/Ip Implementation

    0x0E Get_Attribute_Single Class, Instance, Attribute 0x10 Set_Attribute_Single Class, Instance, Attribute 0x4C Read_Tag_Service Symbolic Segment Addressing Vendor specific service code(see below) 0x4D Write_Tag_Service Read_Tag_Service and Write_Tag_Service using symbolic segment addressing is supported  by the following Rockwell PLC:s: • CompactLogix • ControlLogix  Symbolic segment addressing function is not supported in all versions of the above mentioned  Rockwell PLC:s. Please refer to the documentation for the specific PLC. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 38: Adapter

    Class Attributes No attributes are implemented. Instances Instance 1 is implemented with the following attributes: Access Name Value Vendor ID Device Type Product Code Revision Status Serial Number Product Name Netbiter Services The following services are implemented:  Code Class Instance Service Name 0x01 Get_Attributes_All 0x0E Get_Attribute_Single Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 39 0x0E Get_Attribute_Single 0x10 Get_Attributes_Single 8.2.3 Ethernet Link Object (0xF6) Class Attributes No attributes are implemented (= Rev 1). Instances Instance 1 is implemented with the following attributes:  Access Name Interface Speed Interface Flags Physical Address Services The following services are implemented:  Code Class Instance Service Name 0x0E Get_Attribute_Single Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 40: Local Configuration

    PIN code settings – if using a PIN code for the SIM card (EC250 only) 9.1 Ethernet Connection The PC used to access the local configuration must be on the same Ethernet network subnet  as the gateway. The PC can also be connected directly to the gateway with an Ethernet ca‐ ble. This may require the IP address for the Ethernet interface on the PC to be changed. Finding the IP address of the Netbiter gateway Download and use the IPconfig utility available from www.netbiter.com/support. The  utility scans the local network for Netbiter gateways and displays their IP addresses.  Right‐click on the entry for a gateway in IPconfig and select Open Web Interface to open  its local web server in your default browser. You can also type the IP address directly into  the web browser address field. (MAC = System ID for the gateway)  When using DHCP, you can also find the IP address of the gateway by logging in to the  DHCP server on your network. Contact your network administrator if required. 9.2 USB Connection (EC310 / EC350) Netbiter EC310 and EC350 also have a USB connector for accessing the local web server.  See “Netbiter EC310 / EC350” on page 44. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 41: Netbiter Ec150

    Local Configuration 9.3 Netbiter EC150 9.3.1 Login Enter the IP address of the gateway in a web browser to log in. The default user name is  admin, and the password is the activation code supplied with the unit.  The only changes that should be made locally are the settings for the network connection  and/or firmware updates. All other settings are provided for troubleshooting and informa‐ tional purposes only. Changes made to these other settings will not be synchronized with  Netbiter Argos. 9.3.2 Ethernet Settings When DHCP addressing is enabled the unit will automatically receive the settings for IP  address, subnet mask, default gateway, and DNS. If not using DHCP, these settings must  be entered manually. Contact your network administrator if in doubt.  Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 42: System Settings

    Local Configuration 9.3.3 System Settings This page is mainly used when updating the firmware in the unit.  Updating the Netbiter EC150 Firmware 1. Download the latest firmware file from www.netbiter.com/support to your PC. 2. On the System page, press Browse and locate the firmware file that you downloaded. 3. Press Update to start the update.  Do not close the web browser page while the update is in progress. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 43: Netbiter Ec250

    Local Configuration 9.4 Netbiter EC250 9.4.1 Login Enter the IP address of the gateway in a web browser to log in. The default user name is  admin, and the password is the activation code supplied with the unit. The only changes that should be made locally are the settings for the network connection  and the PIN code. All other settings are provided for troubleshooting and informational  purposes only. Changes made to these other settings will not be synchronized with Net‐ biter Argos. 9.4.2 Modem Settings/PIN code If using a SIM card with an active PIN code, click Enable and enter the PIN code provided  by the card supplier. Click Test PIN to test the PIN code. This setting cannot activate/deactivate PIN code security or change the PIN code on  the SIM card. To do this, install the SIM card in a mobile phone and follow the in‐ structions from the manufacturer. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 44 The unit will automatically switch to GPRS if Ethernet connection is lost. Ethernet only GPRS modem disabled Connection Time Before Restore to Ethernet Sets the time before the gateway should retry the Ethernet connection after a failover to  GPRS. The cycle will be repeated until Ethernet communication has been reestablished. Access Point Name (APN) The identifying name used to connect to a mobile network. The network operator for the  SIM card can supply this information.  User name / Password Required by some mobile network operators.  Click Save settings to save changes. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 45: Proxy Servers

    • Port 5222 If not, the gateway will automatically try to use a port that is open to the Internet.  The ports listed above must be used to communicate with Netbiter Argos. A port on  the LAN side might have another port defined for the proxy, but still needs to use one  of the above ports on the WAN side (port forwarding). Proxy Types The type of proxies that can be used are: • HTTP • Socks 4(a) • Socks 5 9.4.5 Local Proxy Setup 1. Select Netbiter Argos in the local configuration menu. 2. Select the proxy type to use. 3. Enter the proxy server address. 4. Enter the port to use on the LAN side. If left blank, this will be set to port 443. 5. Enter the user name and password (if required). 6. Click Save settings. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 46: Netbiter Ec310 / Ec350

    Local Configuration 9.5 Netbiter EC310 / EC350 9.5.1 Select Login Method The Netbiter EC310/350 models provide local access via either Ethernet or USB cable.  USB connection Connect a USB Micro B cable between the PC and the gateway. After the device driver is  installed, a virtual network card will automatically be created. The local configuration pages of the gateway can now be accessed by entering the IP ad‐ dress 169.254.200.200 in a web browser.  Ethernet Connection Connect an Ethernet cable to the WAN socket on the Netbiter EC310/350, and then log in to  the unit by entering the IP address of the unit in the URL field of a web browser.  See “Ethernet Connection” on page 38 on how to obtain the IP address of the gateway. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 47 Local Configuration 9.5.2 Login Enter the IP address of the gateway in a web browser to log in. The default user name is  admin, and the password is the activation code supplied with the unit. The only changes that should be made locally are the settings for the network connection,  and the modem settings (EC350 only). All other settings are provided for troubleshooting  and informational purposes only. Changes made to these other settings will not be syn‐ chronized with Netbiter Argos. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 48: Wan Settings

    Local Configuration 9.5.3 WAN Settings The WAN interface should be enabled when connecting to Netbiter Argos via Ethernet.  When DHCP addressing is enabled the unit will automatically receive the settings for IP  address, subnet mask, default gateway, and DNS. If not using DHCP, these settings must  be entered manually. Contact your network administrator if in doubt. 9.5.4 Proxy Settings If using a proxy server, check the box and enter the IP address, port and protocol to use. 9.5.5 LAN Settings The LAN interface should be enabled when using EtherNet/IP or Modbus TCP applica‐ tions, or when using the Remote Access feature. Do not connect the LAN and WAN ports to the same physical network. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 49 Enable data connection on modem (Use modem for Argos connection) Sets the modem to be used for communication as default as long as there is a good mobile  signal. If the WAN interface is also enabled, the gateway will automatically switch to Ether‐ net communication if mobile communication is interrupted.  APN (Access Point Name) This is the identifying name used to connect to a mobile network. The network operator for  the SIM card can supply this information.  User name / Password Required by some mobile network operators.  Click Save settings to save changes. Signal Quality, Modem Connection, Radio Access Technology These sections provide information about the modem’s current connection.  Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 50 Local Configuration 9.5.7 Firmware Update 1. Download the latest firmware file from www.netbiter.com/support to your PC. 2. On the Firmware update page, press Browse and locate the new firmware file that  you downloaded. 3. Press Start upgrade to start the update.  Do not close the web browser page while the update is in progress. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 51: Firmware Update

    Firmware Update 10. Firmware Update Alternative Methods The easiest way to perform a firmware update is from the Netbiter Argos web pages. Please  refer to the Netbiter Argos User Manual for instructions.  If Netbiter Argos cannot be used, the firmware update can also be carried out via the local  configuration web pages. See “Local Configuration” on page 38. If none of the above methods can be used, it is also possible to update the firmware in  EC150 and EC250 via a connection to a local PC using the free tool Netbiter Update.  10.1 Using Netbiter Update (EC150/250) Requirements • Null‐modem cable • PC with COM port 1. Download Netbiter Update from www.netbiter.com/support to your PC. 2. Connect a null‐modem cable between the COM port on your PC and the 9‐pin D‐sub  connector on the Netbiter gateway. 3. Start Netbiter Update.  COM Port should already be selected. Leave the Baudrate setting at Auto. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 52 Firmware Update 4. Click Browse to locate the firmware file you downloaded, then click Open. 5. Power OFF the Netbiter gateway.  6. Click Start Programming and wait for the process to complete. 7. Power ON the Netbiter gateway when prompted to do so. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 53 Firmware Update 8. Wait while the tool upgrades the gateway.. 9. When the update is complete you will be asked if you wish to reboot the unit. Click  Yes to complete the process. Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 54: Technical Specifications

    Technical Specifications 11. Technical Specifications 11.1 Dimensions All measurements are in millimetres unless otherwise specified. Netbiter EC150 Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 55 Technical Specifications Netbiter EC220 Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 56 Technical Specifications Netbiter EC250 Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 57 Technical Specifications Netbiter EC310 Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 58 Technical Specifications Netbiter EC350 Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 59: Specifications Ec150 & Ec220

    Storage temperature -40 to +85 °C -40 to +85 °C Housing class IP20 IP20 Power supply 9–24 V DC or AC 9–24 V DC Power consumption Certifications , FCC/IC, PTCRB CE, ROHS Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 60: Specifications Ec250, Ec310 & Ec350

    IP20 IP20 Power supply 9–24 VDC 12–48 VDC Power consumption 4.5 W (typical) 6 W (maximum) Certifications RoHS RoHS RoHS FCC/IC (Pending) ATEX/Haz.Loc (Pending) Telec PTCRB (Pending) JATE PTCRB ATEX/Haz.Loc (Pending) Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...
  • Page 61: Regulatory Notices

    11.4.1 FCC Compliance Statement The design of this equipment complies with U.S. Federal Communications Commission  (FCC) guidelines respecting safety levels of radio frequency (RF) exposure for Mobile de‐ vices. This product contains FCC ID: QIPPHS8‐P RF Exposure ‐ This device is only authorized for use in a mobile application. At least 20 cm  of separation distance between the device and the user’s body must be maintained at all  times. CAUTION: Any changes or modifications not expressly approved by HMS Industri‐ al Networks AB could void the userʹs authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class A  digital device, pursuant to part 15 of the FCC Rules. These limits are designed to pro‐ vide reasonable protection against harmful interference when the equipment is op‐ erated in a commercial environment. This equipment generates, uses, and can  radiate radio frequency energy and, if not installed and used in accordance with the  instruction manual, may cause harmful interference to radio communications. Op‐ eration of this equipment in a residential area is likely to cause harmful interference  in which case the user will be required to correct the interference at his own expense. 11.4.2 Industry Canada Statement This product contains IC ID: 7380A‐PHS8P 11.4.3 Netbiter EC350 Telecommunications Compliance Netbiter EasyConnect Gateway User Manual Doc: HMSI-168-92 Rev: 3.10...