POTABLE WATER PUMP
Installation and Operation Manual
SHURflo has supplied pumps to the manufacturers of RV's for
over 30 years. Our patented Tri-a-fram
pumps deliver smooth, consistent flow at all ranges of operation,
while drawing low current. The balanced diaphragm design
incorporates two precision ball bearings for long life.
SHURflo pumps are 100% tested for proper operation before
they leave the factory. When installed correctly, SHURflo
water pumps will provide years of quiet operation.
A SHURflo pump in combination with a low back pressure
water system can exceed all expectations. For unmatched
reliability and trouble-free performance request SHURflo's
complete line of water system products.
GENERAL INFORMATION
SHURflo realizes that in many instances our pump is being installed as a replacement pump within an existing system.
The following guidelines should be considered to achieve optimum pump operation
MOUNTING
●
The pump can be at the same level or below
the water tank. It may be positioned above
the water tank if needed, as it is capable of a
6 ft.
[1.8
]
vertical prime. Horizontal inlet tubing
M
will allow priming to 30 ft.
[9
M
●
Consider a location that allows easy access
if maintenance is required. The pump should
not be located in an area less than one cubic
foot unless adequate ventilation is provided.
Excessive heat may trigger the integral
thermal
breaker
and
interrupt
When the temperature drops the breaker will
automatically reset and start operation.
●
The pump may be mounted in any position. If
mounting the pump vertically, the pump head should
be in the down position so that in the unlikely event
of a leak, water will not enter the motor.
●
#
Use
8 hardware to fasten the pump. Choose
a solid surface
(thick plywood)
amplify pump operation. The mounting feet
are intended to isolate the pump from the
mounting surface; over-tightening, flattening,
or use of oversized screws will reduce the
ability to isolate vibration/noise.
C O AC H FRAM E O R
" KN O W N G RO U N D"
Bl ack
M O U N T TO A SO LI D SU RFAC E
W I TH # 8 H ARDW ARE
FUSE
( See m ot or l abel f or t he
r ecom m ended am p f use. )
Bat t . +
SW I TC H
( 15 Am p M i n. )
2
# 14
G AUG E
[ 2. 5 M m ]
O R H EAVI ER W I RE
911-352 Rev. H 10/99
®
line of potable water
ELECTRICAL
●
The pump should be on a dedicated
circuit, protected by the specified fuse indicated
on the motor label.
●
A switch rated at or above 15 amps is
]
.
recommended, and must interrupt current flow
on the positive
should use
protected)
●
Wire size
from
operation.
Recommended size wire is
For lengths of 20-50ft.
2
[4
m
]
M
●
The pump must be grounded to a "known
ground"
same size
●
The total current draw on the circuit
exceed 15 amps. If the pump is used in
that will not
conjunction with other components, overload
current protection
wire
requirement of all devices on the circuit.
PO TABLE W ATER
I N LET
C O N N EC TO R
( W at er - pr oof )
FU SE
SW I TC H
VEN T
W ATER TAN K
SH U T- O FF/
D RAI N VALVE
( Typi cal pot abl e w at er syst em show n w i t h opt i onal SH U Rf l o accessor i es)
(+ red)
lead. Marine applications
approved marine duty
U/L
switches and pumps.
2
is based on the distance
(gauge/
m
)
M
the
power
source
to
the
#
14 gauge
use
[6-15
]
M
.
(frame)
. The ground wire must be the
2
as the positive wire.
(gauge/
m
)
M
(fuse or circuit breaker)
size
must
be
for
the
/
"
FLEXI BLE BRAI DED
I . D.
( hi gh psi . )
1
2
TUBI N G 12 i n. LEN G TH S
( r ecom m ended)
STAI N LESS STEEL
C LAM PS ( 2 REQ . )
SCREW
Red
I N - LI N E STRAI N ER
SW I VEL BARB FI TTI N G S*
( N o Seal er Req. D o N ot O ver t i ght en)
( * I ncl uded w i t h r et ai l pum p ki t s)
SH U Rf l o
PU M P
AC C U M U LATO R
*
TW I ST- LO C K STRAI N ER
1/ 2" TH READ ED O R
1/ 2" BARB I N - LI N E M O D ELS
PLUMBING
●
(individual)
SHURflo recommends at least 1ft.
I.D. flexible high pressure tubing to both
[13mm]
ports. Ideally the pumps ports/strainer should
not be connected to plastic or rigid pipe. The
pump's normal oscillation may transmit through
rigid plumbing causing noise, and possibly
(ignition
loosen or crack components.
●
Installation of a 50 mesh strainer
170)
is recommended to prevent foreign debris
pump.
from entering the pump.
2
[2.5
m
]
.
M
●
SHURflo swivel barb fittings provide easy
#
12 gauge
removal if maintenance or access is required.
The fittings are designed with a "taper-seal",
creating a water tight connection when
.
tightened
Neve
compounds on threads. Sealer may enter the
must not
pump causing a failure. Failure due to foreign
debris is not covered under warranty.
Always secure barb tubing connections with
and
properly sized stainless steel clamps to
total
amp
prevent leaks.
●
Rapid cycling may be caused by excessive
back pressure created by one or more of the
following within a plumbing system:
Water filters not on separate feed lines.
Flow restrictors in faucets and shower heads.
Small I.D. lines. Pipe/tubing should be at
least ½"
[13mm]
Restrictive fittings and connections
"T's", feeder lines to faucets, etc.)
SWITCH SHUT-OFF
Restrictions in a plumbing system may cause the
pump to rapid cycle
low flow demands. Cycling should be minimized
to prevent pulsating flow, and to achieve
maximum pump life.
To determine if adjustment is necessary, turn a
faucet
to lower than average flow of water.
ON
The pump should cycle, but its "
be 2 sec. or longer.
leave well enough alone. If the pump is cycling
rapidly increase the setting by turning the screw
clockwise
(1½ turn
for 1 sec. with at least 2 sec. "
cycling cannot be minimized consider removing
( 50 M esh)
plumbing
restrictions
SHURflo Accumulator.
FI LTERED W ATER
FAU C ET
W ATER H EATER
C I TY W ATER
*
W ATER PRESSU RE
REG U LATO R
I N - LI N E FAU C ET
AD APTER
O R
W ALL M O U N T M O D ELS
*
of ½"
[.3
]
M
(SHURflo P/N
hand-
r use Teflon tape or sealing
I.D. for main lines.
(elbows,
during
(ON/OFF within 2 sec.)
time" must
OFF
If the cycling is correct,
until the pump operates
.)
MAX
time".
OFF
or
simply
install
Page: 1 of 2
*
If
a
Need help?
Do you have a question about the Potable Water Pump and is the answer not in the manual?
Questions and answers