Installation Preparation
The goal of installation is to provide a quiet, easy-
to-maintain installation with good flow and low
backpressure. This can be accomplished with
the following guidelines:
• Mount on a solid surface in an accessible
location for strainer cleaning and pump main-
tenance.
• Use flexible high-pressure hose on the pump
inlet and outlet [such as SHURflo Kit 94-591-
00]. The pumps ports and strainer should not
be connected to plastic or rigid pipe, or the
pump's normal motion will transmit through
rigid plumbing causing noise, and possibly
loosening or cracking components.
• Pump must use an adequate 50-mesh strainer
[such as SHURflo 255 series strainers].
• Use a minimum of 1/2" [13mm] Inner Diame-
ter plumbing. Smaller ID plumbing will cause
cavitation, high backpressure, low flow and
noise.
• No need for an accumulator with by-pass pumps.
• Pump is designed for intermittent duty only: Do not use these pumps for running a Reverse-Osmosis [RO] Filtration
System. High pressure-continuous duty usage will shorten the life of the pump and is not covered under warranty.
• Wire Size is 16 GA MINIMUM , 12GA is recommended---See Wire Chart in Electrical Section for minimum sizing.
• Minimum power requirement is a 10 Amp circuit.
• Reduce restrictions on inlet and outlet. This includes small inner diameter shut-off valves, winterizing valves and
elbows.
• If the RV has an Intellitec Pump Controller, it must be rated at 10 or 15 amps; If the controller is rated at 7.5 Amps, a
new controller or a high-amp relay must be used.
Mounting
• Mount the pump within 6 feet of the tank for best performance and pump life. The pump will pull farther, but the farther it
pulls the more work it does, increasing vibration and noise, and reducing the output and pump life.
• Mount pump in a space of at least 1 cubic foot for adequate ventilation to prevent overheating.
• Pump may be mounted in any position.
• Mount pump for easy access for cleaning strainer, maintenance and service.
• Mount pump on a solid surface to prevent vibration and noise.
Electrical
• The pump works best on an individual filtered circuit, protected by the recom-
mended fuse or breaker specified on the label.
• A 15-Amp switch is recommended and should be on the positive lead.
• Wire Sizing: Proper wire sizing is required for good pump operation. If the
wire is too small, low voltage will affect the pump performance and can create
a fire hazard.
SHUT OFF POWER TO THE PUMP WHEN LEAVING THE RV UNATTENDED.
Plumbing
Installation of a strainer is required to prevent debris from entering the pump.
For noise and vibration reduction we recommend at least 18 in. [.5
both ports. The pump ports and strainer should not be connected to plastic or rigid pipe. This hose should be anchored
where it meets the hard plumbing to reduce plumbing vibration.
911-1008-D
4008 RV By-Pass Pump
Installation Guidelines
16GA [1,29mm] min.
CONNECTOR
SWITCH
FUSE
GROUND
SOLID SURFACE
POTABLE H20 INLET
HIGH-PRESSURE
FLEXIBLE HOSE
Solid surface within 6 feet of tank
Minimize flow restrictions in the system
No accumulator needed
Flexible hose on inlet and outlet
Minimize plumbing elbows and valves
] of 1/2" [13mm] I.D. flexible high-pressure hose to
M
By SHURflo
Typical Pump Installation
FUSE
STRAINER
SWIVEL FITTINGS
• Accessible location
• Strainer on pump inlet
• Properly sized wiring
• Proper electrical protection
• Properly sized plumbing
Minimum Wire Size for a 10% voltage drop on a
12VDC, 10 Amp Circuit. Length is the distance from
the power source to pump and back to ground.
Feet
[Meters]
AWG
0 - 25
[0 - 7.6]
25 -50
[7.6 - 15.2]
50 - 70
[15.2 - 21.3]
70 -110 [21.3 - 33.5]
[mm²]
16
[1.3]
14
[2.1]
12
[3.3]
10
[5.3]
Page 1 of 3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Revolution 4008 and is the answer not in the manual?

Questions and answers

Dennis Bycroft
February 2, 2025

What is the cut in pressure 4000 series pumps

Summary of Contents for SHURflo Revolution 4008

  • Page 1 SOLID SURFACE • Use flexible high-pressure hose on the pump POTABLE H20 INLET inlet and outlet [such as SHURflo Kit 94-591- 00]. The pumps ports and strainer should not HIGH-PRESSURE STRAINER be connected to plastic or rigid pipe, or the...
  • Page 2: Operation

    Operation This pump is designed for intermittent duty only. The pump operates normally up to about 40-psi, where a spring-loaded by-pass valve opens, allowing flow back from the output side to the input side, providing smooth, steady flow with virtually no cycling, all the way down to a trickle. As a faucet is opened back up, the pressure will drop, the by-pass will close and full flow is again obtained.
  • Page 3: Troubleshooting

    SHURflo's behalf. SHURflo shall not be liable for any labor, damage or other expense, nor shall SHURflo be liable f or any indirect, incidental or consequential damages of any kind incurred by the use or sale of any defective Product or part.
  • Page 4 ADMISSION H20 • Utilisez un tuyau flexible haute pression sur l’admission POTABLE et la sortie de la pompe [comme le Kit SHURflo 94-591- HAUTE PRESSION FILTRE 00]. Les orifices de la pompe et le filtre ne doivent pas RACCORDS PIVOTANTS être raccordés à...
  • Page 5 La meilleure garantie contre ces dégâts et de vidanger la pompe à fond. Dans le cas de l'utilisation selon les recommandations des fabricants, l'antigel non toxique pour eau potable est sûr pour une utilisation avec les pompes SHURflo. Effectuez ce qui suit pour vidanger la pompe : Vidangez le réservoir d’eau.
  • Page 6: Garantie Limitée

    étrangers n'est pas couverte selon les conditions de cette garantie limitée. SHURflo ne garantit pas de produits physiquement endommagés ou modifiés hors de SHURflo. Les réclamations de garantie peuvent être résolues par un centre de service agréé ou par un centre de service SHURflo. Les renvois sont à expédier avec le port prépayé.

Table of Contents

Save PDF