Description Of Water Heater; Specifications; Technical Data - Ariston EP 10 UR 2 KW Manual

Unvented water heater
Table of Contents

Advertisement

Description of water heater

1)Hot water outlet
2)Temperature and pressure relief
valve (30 litre only)
3)Cold water inlet
4)Control cover
5)Regulation knob
6)Heating neon
Over-sink (EP 30 R 3KW)

Technical data

MODEL
Approval
Capacity (litres)
Current (A)
Tension (V~)
Power
(W)
Immersion Heater Length (mm)
Immersion Heater Type
Immersion Heater Refernce Number
Pressure max.
T & P valve setting
Weight with water
Moisture protection
Over-sink (EP 10/15 OR)
Under-sink (EP 10/15 UR)
EP 10 UR
EP 15 UR
2 KW
2 KW
WRAS
10
15
8.7
220-240 V (50/60 Hz)
2000
160
Single Phase
BS 3456 Section 2.21
6 bar; 12 bar with pressure reducing valve
n/a
16 kg
22 kg
DRIP PROOF IPX1
EP 10 UR 3KW
EP 15 UR 3KW
EP 10 OR 3KW
EP 15 OR 3KW
WRAS
10
15
13
3000
160
n/a
18 kg
24 kg
EP 30 R
3 KW
WRc
30
13
3000
185
90°C/7bar
45 kg
1

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EP 10 UR 2 KW and is the answer not in the manual?

Questions and answers

les
April 2, 2025

where is the thermal cut out on EP 10 ur 2

1 comments:
Mr. Anderson
April 2, 2025

The thermal cut-out on the Ariston EP 10 UR 2 KW is located behind the front cover, which can be accessed by unscrewing the 4 screws on the front.

This answer is automatically generated

helen Tavener
April 26, 2025

What fuse does it need for the electrical supply