USER’S MANUAL This book (user’s and installation manual) is Dear Customer, Thank you for choosing an ARISTON gas water heater. an integral and essential component of the We guarantee that your instantaneous water heater is a product. reliable and technically sound product.
USER’S MANUAL Safety regulations Electrocution from live components. Do not use insecticides, solvents or Key to symbols: aggressive detergents to clean the Failure to comply with this warning appliance. implies the risk of personal injury, in Damage to plastic and painted parts. Do not use the appliance for any use some circumstances even fatal.
USER’S MANUAL WARNING Installation, first ignition and maintenance work must be performed by qualified personnel only, in accordance with the instructions provided. Incorrect installation may harm individuals, animals or property; the manufacturer will not be held responsible for any damage caused as a result.
USER’S MANUAL Ignition procedure ensure that the valve located on the cold water fitting T range D T setting is open 35-48° C 1° C Push button ensure that the gas valve is open 48-50° C 2° C ensure that device Push button for 5 sec...
USER’S MANUAL Disposal and recycling of the unit. Appliance shut-off conditions Our products are designed and manufactured for most of The appliance is protected from the components to be made of recyclable material. malfunctions by means of internal checks performed by the electronic The unit and its accessories have to be adequately P.C.B., which stops the appliance disposed of and the various materials differentiated,...
OVERVIEW Advice for the installer Clean using a cloth dampened with soapy water. Do not use aggressive detergents, insecticides or toxic products. The installation and first ignition of the If the appliance is used in full compliance with current appliance must be performed by qualified legislation, it will operate in a safe, environmentally- personnel compliance...
OVERVIEW suitable manual tools Safety regulations equipment (make sure in particular that the tool is not worn out and that Key to symbols: its handle is fixed properly); use them Failure to comply with this warning correctly and make sure they do not implies the risk of personal injury, in fall from a height.
Page 11
OVERVIEW Make sure the workplace has suitable Before handling, empty all components hygiene and sanitary conditions in that may contain hot water, carrying out terms of lighting, ventilation and any bleeding if necessary. solidity of the structures. Personal injury caused by burns. Personal injury caused by knocks, Descale components,...
PRODUCT DESCRPTION Overall view Legend Overheat thermostat Water outlet temperature probe Water inlet temperature probe Water flow sensor Spark generator Gas valve Gas collector Ignition/Detection electrodes 10. Combustion chamber 11. Heat exchanger 12. Control box 13. Flue connector...
INSTALLATION Before installing the appliance The appliance heats water to a temperature below boiling. WARNING It should be connected to a domestic water mains supply. No flammable items should be left in the Before connecting the appliance, it is necessary to perform the following operations: vicinity of the appliance.
INSTALLATION Water connection Gas connection The illustration shows the connections for the water and The appliance was designed to use gases belonging to gas attachments of the appliance. the categories as shown in the following table. Check that the maximum water mains pressure does not exceed 8 bar;...
INSTALLATION Flue discharge/Air intake duct connections Water circuit diagram Intake/discharge flue duct installation must be in compliance with the regulation in force and instructions provided by the manufacturer The appliance is designed to operate in C mode (by drawing air from outside). When installing an exhaust system be careful when handling the seals, in order to avoid flue gas leaking into the air circuit.
INSTALLATION Table of flue gas exhaust duct lengths WARNING Before performing any work on the Maximum Extension appliance, first disconnect it from the Pipes Exhaust-air (m) diameter Type electrical power supply using the external NEXT EVO X SFT 11/16 (mm) bipolar switch.
COMMISSIONING First ignition Ignition procedure The first start-up must be carried out by a Press the ON/OFF key placed qualified technician. on the control panel, to display the set temperature. 1. Make sure that: For temperature adjustments - The gas valve is closed; see the User Manual paragraph.
COMMISSIONING Checking the gas settings Press the On/Off, appliance forced to minimum power. The display shows a number from “00” to “99”. On the manometer verify the pressure and if necessary press the the (2) buttons to adjust minimum burner pressure as indicated on the gas settings table.
COMMISSIONING Gas setting table NEXT EVO X SFT 11 NEXT EVO X SFT 16 Lower Wobbe index (15°C; 1013 mbares) MJ/m 45.67 80.58 70.69 45.67 80.58 70.69 Gas inlet pressure mbar 28-30 28-30 Gas Burner Pressure MAX mbar 12.10 12.60 15.90 10.8 12.50...
APPLIANCE PROTECTION DEVICES Appliance shut-off conditions The appliance is protected from malfunctions by means of internal checks performed by the electronic P.C.B., which stops the appliance from operating if necessary. In the event of the appliance being shut off in this manner, a code appears on the display which refers to the type of shut-off and the reason behind it.
MAINTENANCE Instructions for opening the casing and performing an internal inspection Before performing any work on the appliance, first disconnect it from the electrical power supply using the external bipolar switch and shut off the gas valve. To access the inside of the appliance, the following is necessary: - loosen the 4 screws, - pull it forward and remove it.
MAINTENANCE Operational test Maintenance is an essential part of the safe and efficient After having carried out the maintenance operations, fill operation of the appliance and ensures its durability. It the appliance and the water circuit. should be performed according to the instructions given in - Begin operating the boiler.
MAINTENANCE Symbols used on the data plate XX X XX XX XX X XX X XX X XX XX XX X XX XX XX X XX XX XX X XX X XX X XX X XX X XX XX XX XX XX XX XX X XX XX...
TECHNICAL DATA Model name : NEXT EVO X 11 SFT 16 SFT CE Certification (pin) 0063CR7772 Type C13 - C33 Gas category II2H3P - I3B/P Maximum nominal heat input 22.0 30.0 Minimum nominal heat input Maximum nominal heat output 19.2 27.4 19.2 27.8...
TECHNICAL DATA ErP Data - EU 814/2013 Model NEXT EVO X 11 SFT 16 SFT see Annex A (*) Equivalent models list Declared load profile 0.044 0.064 Daily electricity consumption Q elec 7.804 24.845 Daily Fuel Consumption Q fuel Indoor Sound power level L Emission of Nitrogen Oxide NOx mg/kWh (*) For the list of equivalent models refer to...
Need help?
Do you have a question about the NEXT EVO X SFT Series and is the answer not in the manual?
Questions and answers