Replacement Parts - Weil-McLain Ultra 3 series User Manual

Gas-fired water boilers ultra 3 series;
Hide thumbs Also See for Ultra 3 series:
Table of Contents

Advertisement

-
gas
fired water boiler

Replacement parts

Replacement parts must be purchased through a local Weil-McLain distributor. When ordering,
specify boiler model and size and include description and part number of replacement part.
Results from using modified or other manufactured parts will not be covered by warranty and
may damage boiler or impair operation.
Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.
The boiler contains ceramic fiber materials
instructions on page 93 of this manual. Failure to comply could result in severe personal in-
jury.
Reinstall boiler jacket front door after startup or servicing
Inspect boiler jacket front door gaskets and reinstall boiler jacket front door after start or
servicing. The boiler front door must be securely fastened to the boiler to prevent boiler from
drawing air from inside the boiler room. This is particularly important if the boiler is located
in the same room as other appliances. Failure to keep the door securely fastened could result in
severe personal injury or death.
Figure 116
Propane conversion kits and instructions
The conversion kits listed below are only for use with Ultra Series 3 boilers. For series 1 or series 2
boilers, refer to the boiler manual or contact Weil-McLain for the correct parts.
Natural to propane conversion — SERIES 3 BOILERS ONLY
(not required for Ultra-399 — adjustment is made with throttle screw, not with orifice)
Sea level (to 5,500 feet altitude)
Model
Kit part #
Ultra-80
383-501-020
540-100-001
Ultra-105
Supplied with boiler
383-500-115
Ultra-155
Supplied with boiler
383-500-120
Ultra-230
Supplied with boiler
540-202-832
Ultra-299
Supplied with boiler
Ultra-80
383-501-021
Boilers marked with this symbol require special installation procedures Do not use the instructions in this manual — use
only the instructions supplied in the conversion kit
112
— Boiler Manual
Kit location
Instructions
SPECIAL
ORDER
In kit only
See page 44
See page 45
See page 45
See page 45
Propane to natural conversion
SPECIAL
ORDER
In kit only
. Use care when handling these materials per
High altitude (above 5,500 feet)
Model
Kit part #
Kit location
Ultra-80LP
383-500-644
Ultra-105
383-500-645
Ultra-155
383-500-646
Ultra-230
383-500-647
Ultra-299
383-500-394
Contact factory
Instructions
SPECIAL
See page 44
ORDER
or kit
SPECIAL
See page 44
ORDER
or kit
SPECIAL
See page 45
ORDER
or kit
SPECIAL
See page 45
ORDER
or kit
SPECIAL
See page 45
ORDER
or kit
Part number 550-100-090/0809

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultra 3 series and is the answer not in the manual?

Questions and answers

Dennis Herrmann
January 26, 2025

Modulation lock out on screen how to reset

1 comments:
Mr. Anderson
February 10, 2025

To reset a modulation lockout on the Weil-McLain Ultra 3 Series boiler, follow these steps:

1. Scroll down to “DIAGNOSTICS” and press the Enter key.
2. Scroll down to “ERRORS” and press the Enter key.
3. Scroll down to “LOCKOUT HISTORY #” and press the Enter key.
4. Select either “MANUAL RESET” or “AUTO RESET” and press the Enter key to display the fault condition.
5. If a manual reset is required, use the manual reset screen on the display.
6. To clear all lockout histories, go to the “ERRORS” screen and hold the Left and Right arrow buttons simultaneously for 5 seconds.

If the issue persists, inspect wiring and sensors as described in the manual.

This answer is automatically generated

Table of Contents

Save PDF