Installation instructions for entry kits using entry panels
LEGD365 061/062/064/066/068/069/060
Description
Components required for 1 to multi apartment kits
Series 7 Handset

System operation

When a call button on the outside entry panel is pressed all the handsets connected to this call button will ring. A
maximum of four handsets can be connected to one call button. There will be a simultaneous ring at the entry panel to
confirm the ringing at the handset(s). When lifting the handset off its cradle inside, communication between the
handset and entry panel can take place. If at the same time any other handset is lifted off its cradle, there will be
common communication with the first handset and the entry panel. At any time any handset in the system can be lifted
off its cradle and there will be a communication link with the entry panel. This is regardless of whether this handset has
been called from the entry panel. The speech volume at the handset(s) and entry panel can be set independently.
The entrance door or gate can be operated using the door/gate release pushbutton provided on the handset. A second
pushbutton is provided to operate auxiliary functions such as other features on the entrance gate operator or switch a
light outside the front door or gate. A pushbutton is provided on the entry panel to illuminate the call button label and
improve usability in dark conditions. This latest generation of entry panels, the Series 7, simplifies the installation of the
system, and through improved weatherproofing enhances the long term reliability of the product.
Entry Panel
(Made up in 2 button increments
to suit number of call buttons required)
Ground
85
Ground
Surface Box
mild steel or
3CR12 stainless steel
with light grey epoxy coating
(Select size according to
configuration of entry panel)
Power supply unit
CP13E/12V
alternatively connect to
12V DC battery of gate motor

Advertisement

loading
Need help?

Need help?

Do you have a question about the LEGD365 061 and is the answer not in the manual?

Questions and answers

Summary of Contents for LEGRAND LEGD365 061

  • Page 1: System Operation

    Installation instructions for entry kits using entry panels LEGD365 061/062/064/066/068/069/060 Description Components required for 1 to multi apartment kits Surface Box Entry Panel mild steel or (Made up in 2 button increments 3CR12 stainless steel to suit number of call buttons required)
  • Page 2 Line diagram for Series 7 entry panel 4+(n-4) 4+(n-2) 12V DC Power Supply only. See note 1 Door strike Gate release CP13E/12V Power supply Table of recommended cross-sections Min. Power Number Connections Cross-sections (mm²) Supply of wires 50 m 100 m 200 m 9, 10 3, 4, 5...
  • Page 3 Wiring diagram for Series 7 entry panel SITUATION: 1. The gate / door release is used to operate a gate motor and the power supply to the system is either 12V DC or AC. 2. The gate / door release is used to operate a low current door strike and the power supply to the system is strictly 12V AC.
  • Page 4 Wiring diagram for Series 7 entry panel SITUATION: 1. Wiring diagram for Series 7 where the gate/door release operates an electric door strike, rim lock or magnetic lock and the power supply is 12V DC. Rimlock CP79v2 Pulse Stretcher 2 3 4 5 See note 3 Series 7 2 3 4 5...
  • Page 5 Extensions Up to four handsets for the same call. For two, three or four handsets, multiply the cross-sections by two, three or four (1E,2,9,10). 2 3 4 5 2 3 4 5 Series 7 Series 7 Series 7 entry panel Accessory Connection of an electric rim lock to entry panel using an AC power supply only.
  • Page 6 Installation FIT CALL BUTTON ADDRESS LABELS POSITION ENTRY PANEL 1.Position entry panel on wall 2. Alternatively mount the entry 3. Mount surface box into position 4. To fit the call button address 5. Grip the outside of the frame as adjacent door or entrance gate.
  • Page 7 Checking ±12V ±12V Check Voltage at entry panel The call sounds in the street panel The volume in the street panel and and the handset the handset is correct Adjust the volume in the street panel Check the door opening Check the illumination of the and in the handset.
  • Page 8 CENTURION THE AUTOMATIC CHOICE CENTURION SYSTEMS (PTY) LTD HEAD OFFICE: TEL: +27 (0)11 699-2400, FAX: +27 (0)11 704-3412 or 462-6669 148 EPSOM AVENUE, NORTH RIDING P .O. BOX 506, CRAMERVIEW, 2060 SOUTH AFRICA WEB: http://www.centsys.co.za General information e-mail: info@centsys.co.za Sharecall Number: 0860-CENTURION FOR TECHNICAL SUPPORT CONTACT: JOHANNESBURG CENTRAL/WR .

This manual is also suitable for:

Legd365 062Legd365 066Legd365 064Legd365 068Legd365 069Legd365 060