Premier Elite 8XP-W & 32XP-W Installation Manual 2. Premier Elite 8XP-W & 32XP-W Texecom has developed a new method of wireless security signalling based on the concept of mesh networking. Mesh-networking is the process whereby every single wireless device is capable of receiving and retransmitting any signal from any other wireless device on the network.
168™ Premier Elite 640™ Premier Elite 32XP-W take 4 address slots on the network, Premier Elite 8XP-W take one address System Requirements To enable all of the advanced functionality and diagnostics capability Ricochet™ MT2 the following are minimum requirements:- •...
Premier Elite 8XP-W & 32XP-W Installation Manual System Design Considerations To ensure correct setup and operation of the Wireless Network it is important that the following procedures are used when learning and placing devices. Multiple Expander Systems Ricochet MT2 When using multiple expanders great care should be taken when designing the system. Each expander should be treated as its own wireless network;...
Premier Elite 8XP-W & 32XP-W Installation Manual 5. System Overview 1 2 3 4 1 2 3 4 1: Engineers Keypad Connection An engineer’s keypad (Premier/Elite LCD keypad and interface lead) can be temporarily plugged onto this connector to allow system programming and testing. (Functions dependent on Panel firmware version) Set the keypad address switches to all on.
Page 10
Premier Elite 8XP-W & 32XP-W Installation Manual 5: Lid Tamper When open puts the system into commission mode and digitally attenuates the receiver signal by 15Db. 6: Programming LED’s Allows programming of devices directly to the receiver, in conjunction with the learn switch.
Premier Elite 8XP-W & 32XP-W Installation Manual Mounting the Expander Remove each screw cap by inserting a flat bladed screwdriver into the slot and turning anti- clockwise, excessive force is NOT required. Remove both of the cover screws and put them in a safe place along with the screw caps.
Premier Elite 8XP-W & 32XP-W Installation Manual The networks are made up of four terminals incorporating power and data. To ensure correct operation, all four terminals on the device must be connected to the corresponding terminals on the control panel or previous device.
Premier Elite 8XP-W & 32XP-W Installation Manual 6. Programming It is highly recommended that you upgrade the Panel Firmware to the latest version to ensure full compatibility; however the system is backwards compatible as detailed in the table on page 5.
Premier Elite 8XP-W & 32XP-W Installation Manual Device Modes of Operation Always Awake This mode should only be used on devices which are required to signal at all times and is the default setting for the Impaq Contact-W and Impaq Plus-W.
Page 16
Premier Elite 8XP-W & 32XP-W Installation Manual * E nter zone number e.g 009 = Zone 009 * ...
Premier Elite 8XP-W & 32XP-W Installation Manual Premier Elite SmartKey™ Introduction Premier Elite SmartKey™ are now learnt and all functionality managed through the “Setup Users” Menu. Ricochet™ MT2 and Premier Elite Series V2 firmware upgrades add additional capabilities to the management of Premier Elite SmartKey™.
Premier Elite 8XP-W & 32XP-W Installation Manual Deleting a Premier Elite SmartKey™ Deleting the Premier Elite SmartKey™ from the user is a similar process to learning, at the , the Premier Elite SmartKey™ will be appropriate point in the menu press ...
Premier Elite 8XP-W & 32XP-W Installation Manual Premier Elite 24/48/88/168/640 V1.00 Premier 24 V8.24, 48/88/168 V8.15>later When using the 8XP-W it is only possible to learn devices to slots 1-8 on the expander. Slots 9-32 will still be shown in Ricochet Monitor, and on the keypad, however no devices can be learned to them.
Premier Elite 8XP-W & 32XP-W Installation Manual Premier 24 V7.00-V8.23, 48/88/168 V7.00 – V8.14, 640 V7.00-V8.15 Option Switch Settings For V7.00-V8.11 of firmware switch 1 2 & 3 should be ON for all panels. For Versions prior to V7.40 on the Premier 24, Learned devices should be mapped to zones 9-24 only, it is not possible to map to Zones 1-8.
Premier Elite 8XP-W & 32XP-W Installation Manual Follow these instructions to learn devices to the control panel AFTER they have been learnt to the receiver. / ...
Premier Elite 8XP-W & 32XP-W Installation Manual Premier 412/816/816 Plus & 832 PV1.00> Premier 412/816 V11.10 & Later, Premier 832 V4.10 & Later Follow these instructions to learn devices to the system, once completed follow the relevant section of the control panel manual to programme zones and user attributes.
Premier Elite 8XP-W & 32XP-W Installation Manual Removing Detectors If a detector is no longer required it must be unassigned from the system. To remove a detector from a zone, proceed as follows: Enter Engineers code Then press then ...
Page 25
Premier Elite 8XP-W & 32XP-W Installation Manual SmartKey™ are assigned to users as follows: Enter Engineers code Then press then Enter User Number ...
Premier Elite 8XP-W & 32XP-W Installation Manual SmartKey™ If a SmartKey™ is no longer required it must be unassigned from the system. To remove a SmartKey™ from a user, proceed as follows: Enter Engineers code Then press then ...
Premier Elite 8XP-W & 32XP-W Installation Manual Premier 412/816 V10.5 – V11.07 & Premier 832 V3.50.-.V4.07 Follow these instructions to learn devices to the system, once completed follow the relevant section of the control panel manual to programme zones and user attributes.
Premier Elite 8XP-W & 32XP-W Installation Manual Select engineer’s mode by entering the engineer code followed by / then . Enter to select the Assign Radio Device menu, if an error tone is generated then the receiver is not installed or configured correctly.
Premier Elite 8XP-W & 32XP-W Installation Manual SmartKey™ All SmartKey™ must be assigned to one of the available users on the system. The users available will vary depending on the control panel: Control Panel Available Users Premier 412 Users 1 to 31...
Premier Elite 8XP-W & 32XP-W Installation Manual Removing SmartKey™ If a SmartKey™ is no longer required it must be unassigned from the system. To remove a SmartKey™ from a user, proceed as follows: Enter Engineers code Then press then ...
Premier Elite 8XP-W & 32XP-W Installation Manual Learning Devices directly to the 8XP-W & 32XP-W this is only available in legacy mode. All devices can be learnt directly to the receiver. Device attributes cannot be changed when learning devices in this mode, all devices will use their factory default.
Premier Elite 8XP-W & 32XP-W Installation Manual Using the Engineers Keypad The Engineers Keypad can be connected directly to the expander, and has the following features & functions. Learning & Deleting devices is only available in Legacy Mode Device list...
Page 34
Premier Elite 8XP-W & 32XP-W Installation Manual Change Device attributes Not available on Ricochet MT2 systems Device attribute changes should be saved by either pressing the / key after each device change, or by pressing the / key after scrolling through the devices and making multiple ...
Page 35
Premier Elite 8XP-W & 32XP-W Installation Manual Change SmartKey™ attributes Not available on Ricochet MT2 Systems SmartKey™ attribute changes should be saved by either pressing the key after each SmartKey™ change, or by pressing the key after scrolling through the devices and making multiple changes.
Premier Elite 8XP-W & 32XP-W Installation Manual 2 Hops In this example the device is hopping through device 18 & 6 and the relevant signal strength is shown. Update Devices Used to immediately update devices (NOT SmartKey™) attributes when changed in the Device List menu.
Premier Elite 8XP-W & 32XP-W Installation Manual Walktest Mode Used to initiate & stop Walktest Mode / / Wh en u pd atin g d evic es a mes s ag e is s en t to all to ena ble th e LE D’...
Premier Elite 8XP-W & 32XP-W Installation Manual System Status Shows various System Details = Receiver connected to Premier Network correctly = Not Connected = Firmware version of the Premier 8XP-W/32XP-W = Receiver is being Jammed ...
Premier Elite 8XP-W & 32XP-W Installation Manual Device Status Indications (V1 only) On the top line of the display the following may be seen depending on the device and status:- = all devices Front Tamper ...
Premier Elite 8XP-W & 32XP-W Installation Manual 7. Ricochet™ MT2 Diagnostics Engineer Utilities now includes a new Ricochet™ Diagnostics menu. This menu displays information about the live system, and is split into Premier Elite SmartKey™ and Ricochet™ devices via Zones and Users.
Page 41
Premier Elite 8XP-W & 32XP-W Installation Manual This display shows that no message has been received yet, this would normally be seen on a recently powered up system, wait 15 minutes from power up before checking the diagnostics ...
Page 42
Premier Elite 8XP-W & 32XP-W Installation Manual Premier Elite SmartKey™ Messages The chosen user does not have a Premier Elite SmartKey™ associated with them. The Premier Elite SmartKey™ is not switched on ...
Premier Elite 8XP-W & 32XP-W Installation Manual Ricochet Diagnostics Menu Us e to s c roll to R ic oc het Diag ...
Premier Elite 8XP-W & 32XP-W Installation Manual 8. Modes of Operation Commission Mode Expander The expander has a Commission Mode, which when operated ensures secure communications with devices on the system. Commission Mode is automatically enabled when the expander is in tamper.
Premier Elite 8XP-W & 32XP-W Installation Manual Switch 3 on the expander controls how MAG 2/COM reports to the control panel. By default the switch is on and anything connected to MAG 2/COM will report as a tamper. When switch 3 is OFF MAG 2/COM will report as alarm.
Premier Elite 8XP-W & 32XP-W Installation Manual System Devices Auto Mode Auto Mode is the default device setting for the Premier Elite XT-W QD-W when used on V1 systems. When in Auto Mode, devices poll at 15 minute intervals. Following activation, devices will not transmit the same activation again for a period of 3 minutes.
Premier Elite 8XP-W & 32XP-W Installation Manual Premier Elite SmartKey™ LED Indications SmartKey™ Status LED The Status LED has four colours. This LED cannot be disabled. Pink = Power Up or Down S martKey s tatus LE D FUNC TION 1/PC C ontrol 1...
Premier Elite 8XP-W & 32XP-W Installation Manual The Function Keys use the PC Control virtual outputs on the control panel and are pre assigned, in the case of the Premier 24/412/816 & 832, only function buttons 1 & 2 may be used.
Premier Elite 8XP-W & 32XP-W Installation Manual Battery Considerations Battery life for all devices will be determined by system complexity, the number of devices that hop, and the use of the Always Awake mode. In a typical system, battery life should be up to 4 years for devices, hopping devices should achieve between 2-3 years.
For more information see: www.recyclethis.info. RoHs Directive: 2002/95/EC RoHS Compliant. Hereby, Texecom declares that this device does not contain lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated depheny ethers (PBDE) in more than the percentage specified by EU directive 2002/95/EC, except exemptions stated in EU directive 2002/95/EC annex.
As the Premier Elite 8 XP-W & 32XP-W expander is not a complete alarm system but only a part thereof, Texecom cannot accept responsibility or liability for any damages whatsoever based on a claim that the Premier Elite 8 XP-W & 32XP-W expander/s failed to function correctly. Due to our policy of continuous improvement Texecom reserve the right to change specification without prior notice.
Texecom Limited, Bradwood Court, St. Crispin Way, Haslingden, Lancashire BB4 4PW, England. Technical Support: UK Customers Tel: 08456 300 600 (Calls charged at local rate from a BT landline. Calls from other networks may vary.) International Customers Tel: +44 1706 233875 Email: techsupport@texe.com...
Need help?
Do you have a question about the Premier Elite 8XP-W and is the answer not in the manual?