NEC Univerge SV8100 Installation Manual page 79

Mycalls
Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Multiple Units
When using multiple units, the same concept applies to the Channel Mapping for each trunk on the
PBX. The only difference is each Call Recording unit must be given a unique ID; this would usually
be 1, 2, 3 or 4 as applicable. By default each unit comes with unit ID 1.
The following procedure describes how to change the ID of a Call Recording unit. Changing the ID of
the unit will not drop or terminate calls that are in progress.
1. Unplug all Call Recording units and plug in the unit that you want to set the ID on.
2. From the Start / Programs / Retell / Sense / Services menu, stop the Retell service.
3. Browse into the installation folder (i.e.) c:\program files\retell\sense\bin and start the vps.exe
application. The following screen is shown; the top line shows a device number, take note of
this device number.
4. Type h then press enter for the help menu.
5. Now type sdd device number where device number is the number noted in step 3.
For example if the device is 0, type sdd 0 and press enter. No reaction is given back. Typically
you would type sdd 0.
6. Type d1 and press enter.
7. When prompted enter the password retell and press enter.
8. You will be presented with the following menu:
9. From the menu select 4 for hardware parameters
10. In the hardware parameters menu, select option 2, set CS ID
11. Type in the ID that you require for the unit.