Mitsubishi Electric PEFY-WP15 VMS1-E Installation Manual

Indoor unit
Hide thumbs Also See for PEFY-WP15 VMS1-E:

Advertisement

Air-Conditioners
INDOOR UNIT
PEFY-WP15,20,25,32,40,50 VMS1-E

INSTALLATION MANUAL

For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.
INSTALLATIONSHANDBUCH
Zum sicheren und ordnungsgemäßen Gebrauch der Klimageräte das Installationshandbuch gründlich durchlesen.
MANUEL D'INSTALLATION
Veuillez lire le manuel d'installation en entier avant d'installer ce climatiseur pour éviter tout accident et vous assurer d'une utilisation correcte.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, leggere attentamente questo manuale di installazione prima di installare il condizionatore d'aria.
INSTALLATIEHANDLEIDING
Voor een veilig en juist gebruik moet u deze installatiehandleiding grondig doorlezen voordat u de airconditioner installeert.
MANUAL DE INSTALAÇÃO
Para segurança e utilização correctas, leia atentamente este manual de instalação antes de instalar a unidade de ar condicionado.
ΕΓΧΕΙΡΙΔΙΟ ΟΔΗΓΙΩΝ ΕΓΚΑΤΑΣΤΑΣΗΣ
Για ασφάλεια και σωστή χρήση, παρακαλείστε διαβάσετε προσεχτικά αυτό το εγχειρίδιο εγκατάστασης πριν αρχίσετε την εγκατάσταση της μονάδας
κλιματισμού.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для осторожного и правильного использования прибора необходимо тщательно ознакомиться с данным руководством по установке до
выполнения установки кондиционера.
MONTAJ ELKİTABI
Emniyetli ve doğru biçimde nasıl kullanılacağını öğrenmek için lütfen klima cihazını monte etmeden önce bu elkitabını dikkatle okuyunuz.
PŘÍRUČKA K INSTALACI
V zájmu bezpečného a správného používání si před instalací klimatizační jednotky důkladně pročtěte tuto příručku k instalaci.
NÁVOD NA INŠTALÁCIU
Pre bezpečné a správne použitie si pred inštalovaním klimatizačnej jednotky, prosím, starostlivo prečítajte tento návod na inštaláciu.
TELEPÍTÉSI KÉZIKÖNYV
A biztonságos és helyes használathoz, kérjük, olvassa el alaposan ezt a telepítési kézikönyvet, mielőtt telepítené a légkondicionáló egységet.
PODRĘCZNIK INSTALACJI
W celu bezpiecznego i poprawnego korzystania należy przed zainstalowaniem klimatyzatora dokładnie zapoznać się z niniejszym podręcznikiem
instalacji.
PRIROČNIK ZA NAMESTITEV
Za varno in pravilno uporabo pred namestitvijo klimatske naprave skrbno preberite priročnik za namestitev.
INSTALLATIONSHANDBOK
Läs den här installationshandboken noga innan luftkonditioneringsenheten installeras, för säker och korrekt användning.
PRIRUČNIK ZA UGRADNJU
Radi sigurne i ispravne uporabe, temeljito pročitajte ovaj priručnik prije ugradnje klimatizacijskog uređaja.
РЪКОВОДСТВО ЗА МОНТАЖ
За безопасна и правилна употреба, моля, прочетете внимателно това ръководство преди монтажа на климатизатора.
MANUAL CU INSTRUCŢIUNI DE INSTALARE
Pentru o utilizare corectă şi sigură, vă rugăm să citiţi cu atenţie acest manual înainte de a instala unitatea de aer condiţionat.

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PEFY-WP15 VMS1-E

  • Page 1: Installation Manual

    Air-Conditioners INDOOR UNIT PEFY-WP15,20,25,32,40,50 VMS1-E INSTALLATION MANUAL For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH Zum sicheren und ordnungsgemäßen Gebrauch der Klimageräte das Installationshandbuch gründlich durchlesen. MANUEL D’INSTALLATION Veuillez lire le manuel d’installation en entier avant d’installer ce climatiseur pour éviter tout accident et vous assurer d’une utilisation correcte. MANUAL DE INSTALACIÓN Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de aire acondicionado.
  • Page 2 [Fig. 1-4-1] [Fig. 3-1-2] (Unit: mm) (Viewed from the direction of the arrow A) 100~200 A Air vent valve [Fig. 3-1-1] 50~150 [Fig. 3-1-4] (Viewed from the direction of the arrow B) [Fig. 3-1-3] 100~200 [Fig. 3-1-5] (Viewed from the direction of the arrow B) A Electric box H Intake air B Ceiling...
  • Page 3 [Fig. 5.1.1] [Fig. 5.1.2] [Fig. 5.2.1] C Nuts (field supply) D Washers (accessory) A Unit body A Indoor unit’s bottom surface B Lifting machine E M10 hanging bolt (field supply) [Fig. 6.2.1] A Drain pipe (O.D. ø32) [Fig. 6.3.1] Max. 20m Correct piping Max.
  • Page 4 [Fig. 7.2.1] [Fig. 7.2.2] A Locally procured insulating material for pipes B Bind here using band or tape. C Do not leave any opening. D Lap margin: more than 40 mm E Insulating material (field supply) F Unit side insulating material A Water pipe: To HBC unit [Fig.
  • Page 5 [Fig. 9.2.3] [Fig. 9.2.4] 9~13 VDC A Non-polarized B TB15 24~30 VDC C Remote Controller D TB5 (A, B) [Fig. 9.3.1] [Fig. 9.3.2] A Terminal box A Screw holding cover (2pcs) B Knockout hole B Cover C Remove [Fig. 9.3.3] [Fig.
  • Page 6: Table Of Contents

    • Always use an air cleaner, humidifier, electric heater, and other acces- work together with the outdoor unit, as required. sories specified by Mitsubishi Electric. • The indoor models should be installed the ceiling over than 2.5 m from floor.
  • Page 7: Before Getting Installed (Moved) - Electrical Work

    1.3. Before getting installed (moved) - elec- • Safely dispose of the packing materials. - Packing materials, such as nails and other metal or wooden parts, may trical work cause stabs or other injuries. - Tear apart and throw away plastic packaging bags so that children will not Caution: play with them.
  • Page 8: Securing Installation And Service Space

    3.2. Securing installation and service space 3.3. Combining indoor units with outdoor units • Select the optimum direction of supply airflow according to the configuration of the room and the installation position. For combining indoor units with outdoor units, refer to the outdoor unit installa- •...
  • Page 9: Confirming Drain Discharge

    3. Perform insulation work on the drain pipe (O.D. ø32 PVC TUBE) and on the 3. Perform the test run in cooling mode, or connect the connector to the ON socket (including elbow). side of SWE on the Indoor controller board. (The drain pump and the fan are forced to operate without any remote controller operation.) Make sure using 4.
  • Page 10: Water Treatment And Quality Control

    7.3. Water treatment and quality control 5. Leakproof the water pipework, valves and drain pipework. Leakproof all the way to, and include pipe ends so that condensation cannot enter the insu- To preserve water quality, use the closed type of water circuit. When the circulat- lated pipework.
  • Page 11: Electrical Wiring

    9. Electrical wiring Precautions on electrical wiring 5. Never connect the power cable to leads for the transmission cables. Other- wise the cables would be broken. Warning: 6. Be sure to connect control cables to the indoor unit, remote controller, and the outdoor unit.
  • Page 12: Connecting Remote Controller, Indoor And Outdoor Transmission Cables

    Warning: • Be sure to use specified wires for connections and ensure no external force is imparted to terminal connections. If connections are not fixed firmly, heat- ing or fire may result. • Be sure to use the appropriate type of overcurrent protection switch. Note that generated overcurrent may include some amount of direct current. Caution: •...
  • Page 13: Setting Addresses

    9.6. Setting addresses 9.7. Sensing room temperature with the built-in sensor in a remote controller (Be sure to operate with the main power turned OFF.) • There are two types of rotary switch setting available: setting addresses 1 to If you want to sense room temperature with the built-in sensor in a remote con- 9 and over 10, and setting branch numbers.
  • Page 14 HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Authorized representative in EU: MITSUBISHI ELECTRIC EUROPE B.V. Authorized representative in EU: MITSUBISHI ELECTRIC EUROPE B.V. HARMAN HOUSE, 1 GEORGE STREET, UXBRIDGE, MIDDLESEX UB8 1QQ, U.K.

Table of Contents