Ring Over Page; Station Message Detail Recorder (Smdr); System Programming From A Pc (Pcmmc) - Samsung DCS 70 Installation Manual

Digital communications systems
Table of Contents

Advertisement

SAMSUNG DCS 70
INSTALLATION MANUAL
Common bell control can be used with station hunt groups, individual stations and universal answer.
The relay contacts are rated at 24V DC, 1 Amp.
WARNING. Do not attempt to connect 240V AC power to these

RING OVER PAGE

When a customer provided paging system is installed, incoming calls can be assigned to ring over the
paging output. Program the line, or lines, to ring a hunt group. Use MMC 601 to assign Ring Over
Page (ROP) as a destination in this hunt group. Ring over page can be used for day or night operation
or both.

STATION MESSAGE DETAIL RECORDER (SMDR)

On the DCS 70 system, connect the customer provided printer or TIMS system to one of the RS232C
Serial Interfaces via an Austel approved data LIU
The cable to the printer or TIMS system should be no longer than 5 metres if unshielded cable is used.
The cable should be no longer 20 metres if shielded twisted pair cable is used.
Use MMC 725 to set the SMDR print options.

SYSTEM PROGRAMMING FROM A PC (PCMMC).

The DCS70 system can be programmed by a Personal Computer (PC) by running the PCMMC
application program on the PC.
On the DCS70 system, connect the PC to a serial port on a MISC1 or MISC2 card.
The wiring for the connecting cable between the P.C and the DCS 70 Misc card is detailed below.
Misc Card DB9
TXD 2
RXD 3
GND 5
DTR 4
Figure 6-2
Connecting Cable for PC & MISC Card
Connect the P.C to the serial port of the MISC 1 or 2 card via an ACA approved data LIU.
System IO port 1 is the default PCMMC port, this is the RS232 port on the front of the MISC 1/2
card (closest to front cover of the DCS 70).
contacts.
P.C Com Port
(male)
Page 6-3
P.C Com Port
DB9
DB25
2
3
3
2
5
7
4
20
th
10
January, 2000

Advertisement

Table of Contents
loading

Table of Contents