CONNECTING TO POWER TOOLS (FIG. 1, 4, 5)
WARNING: Only use the outlet (m) for
purposes specified in the instructions.
1. Plug the vacuum power cord into an
appropriate outlet.
2. Plug the power tool into the outlet (m).
NOTE: See Power connection data of
power tool under Technical Data for the
power allowance of the tool to be plugged into
the outlet (m).
3. Turn on/off/tool control switch (o) to the
ACTIVATION position
vacuum to be turned on and off automatically
by the power tool.
NOTE: The vacuum cleaner starts automatically
within 0.5 seconds and continues to run for
15 seconds after the power tool has been
turned off.
4. To switch back to manual mode, turn the on/
off/tool control switch (o) to the ON position (  ).
In manual mode the tool and the vacuum are
turned on and off independent of each other.
5. Your D
WALT construction dust extractor is
e
fitted with the D
WALT AirLock connection
e
system. The AirLock allows for a fast, secure
connection between the suction hose (g) and
power tool. The AirLock connector (w) connects
directly to D
WALT compatable tools or through
e
the use of an AirLock adapter (available from
your local D
WALT supplier). Refer to the
e
Accessories section for detail on available
adapters.
NOTE: If using an adapter ensure it is firmly
attached to the tool outlet before following the
steps below.
a. Ensure the collar on the AirLock connector
is in the unlock position. Align notches (v) on
collar and AirLock connector as shown for
unlock and lock positions.
b. Push the AirLock connector onto the adapter
connector point.
c. Rotate the collar to the locked position.
NOTE: The ball bearings inside collar lock
into slot and secure the connection.The
power tool is now securely connected to the
dust extractor.
AUTOMATIC FILTER CLEANING SYSTEM
This vacuum has a highly effective filter cleaning
system which minimizes filter clogging. Every
30 seconds, one of the two filters gets automatically
. This allows the
cleaned. The cleaning process alternates between
the filters and continues through the life of the unit.
NOTE: It is normal to hear a clicking sound during
this process.
NOTE: After many hours of operation the automatic
filter cleaning system may not be effective. When
this happens the filters will need to be cleaned or
replaced. Refer to Filter under Maintenance.
PARKING BRAKE (FIG. 1, 6)
The parking brake will lock one wheel in place to
prevent vacuum from rolling.
1. To engage parking brake, depress
the brake button (x) to snap the brake into the
locked position.
2. To disengage parking brake, depress the brake
button and brake will snap into the unlocked
position.
REMOVE / CHANGE USED DUST COLLECTION BAG (FIG. 1)
WARNING: Appropriate personal
protective equipment like dust mask and
gloves should be used while handling
used dust bags.
1. Turn off vacuum and unplug cord from outlet.
2. Close the twist-lock hose inlet (j) with the inlet
plug (s).
3. Unlatch canister latches (d) and remove vacuum
head (c)
4. Pull the collection bag carefully from inlet (j).
5. Seal the collection bag opening tightly when
removing it from the machine.
6. Dispose of collection bag in appropriate
container according to statutory provisions.
WET PICK UP APPLICATIONS (FIG. 1, 7)
WARNING: DO NOT connect power
tools to outlet (m) when using the
vacuum for wet pick up.
WARNING: Plug vacuum into residual
current device (RCD) protected outlet
when using the vacuum for wet pick up.
WARNING: If foam or liquid escapes
from the machine, switch off
immediately.
CAUTION: Clean the water level limiting
device regularly and examine it for signs
of damage.
NOTICE: DO NOT remove ball float
(y), doing so will cause damage to the
vacuum. The ball float keeps water from
entering the motor.
E NGLISH