TEST NO. 9: Steering and Lift/Lower Gear Pump Flow

(Using Tester with Pressure Gauges and Flow Meter)
TO STEERING CIRCUIT
FROM
RESERVOIR
Hydraulic System (Rev. B)
NOTE: LIFT/LOWER GEAR PUMP FLOW TEST SHOWN
TO LIFT/LOWER CIRCUIT
1.2
1.2
.58
FROM OIL
FILTER
Page 4 - - 40
TRACTION
2.48
CIRCUIT
High Pressure
Low Pressure
Return or Suction
Flow
Groundsmaster 4000--D