Parameters used for the data format
The following 2 types of parameters are used for command and response data:
(1) ON/OFF (2) Special Parameter
Each parameter is as follows:
(1) ON/OFF
Shows the status (ON or OFF) of the unit, such as POWER and HIDE.
Character
0
1
(2) Special parameters
Operation mode parameters
Character
0000
0001
0002
0003
0004
DHCP client parameters
Character
0
1
IP address parameters
Display the IP address using the dot ("." (2HE)) delimiter.
Example: "192.168.0.10"
External control command table
Function
Power
Hide
Operation Mode
DHCP Client
IP Address
Network Restart
NOTE:
● After configuring the ADHCP ClientB and AIP AddressB, execute ANetwork RestartB.
Downloaded From projector-manual.com JVC Manuals
Hex
Meaning
30
OFF
31
ON
Hex
30 30 30 30
Standby state
30 30 30 31
Power ON state
30 30 30 32
Cooling state
30 30 30 33
Emergency cooling state
30 30 30 34
Emergency state
Hex
Meaning
30
DHCP
31
Static IP
Setting
Command
Power On
U0F
(OFF)
U00
-
UA0
UD2
UD3
UDC
Meaning
Asking
ELSE
Power On
ELSE
-
-
(ON)
-
-
-
Data Type
ON/OFF
Special Parameter
-
-
-
Standby...
-
DHCP...
-
192.168. ...
-