10.11 Air Pressure Switch, Part No. 227127 -
diagram 10.6
Gain Access as Section 5.2.
Remove the air pressure tubes and electrical connections from
the switch, release the screws and remove the switch.
When fitting the replacement make sure that the plastic tubes
are fitted as shown in diagram 10.6 and the electrical connections
are made, as diagram 9.4.
10.12 Fan, Part No. 227034 - diagram 10.7
Refer to Section 5.3.
Remove the electrical connections and disconnect the air
tubes.
Note: Remove the electrical connections by pulling insulation
boots only.
If top outlet installation: Remove air deflector, or it may just be
swung back by loosening the wing nuts, to enable fan assembly
to be removed, see diagram 8.7 and Section 5.3.
Remove the fan assembly securing screw at the front, then
withdraw the assembly.
The fan is secured to the flue hood by three screws.
The polarity of the electrical connections is not important.
10 Replacement of Parts
ELECTRICAL
CONNECTIONS
IMPORTANT:
REMOVE ELECTRICAL CONNECTIONS
BY GRIPPING THE BOOT ONLY
ASSEMBLY
27
SECURING
SCREW (2)
AIR
PRESSURE
SWITCH
CLEAR
AIR TUBE
RED
AIR TUBE
ELECTRICAL
CONNECTIONS
FAN
FAN
SECURING
SECURING
SCREW (3)
SCREW
RED
AIR TUBE
Diagram 10.6
CLEAR
AIR TUBE
Diagram 10.7
2000225227C
Need help?
Do you have a question about the Micron 50FF and is the answer not in the manual?
Questions and answers