Summary of Contents for Viking Range 30” W. Models
Page 1
Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For more product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.com Freestanding Gas Self-Clean Ranges F1738R EN (020708J)
IMPORTANT: GENERAL INFORMATION WARNING WARNING PLEASE READ AND FOLLOW •WARNING: The use of cabinets for storage above the IF THE INFORMATION IN THIS MANUAL IS appliance may result in a potential burn hazard. • Before beginning, please read these instructions ELECTRICAL GROUNDING INSTRUCTIONS NOT FOLLOWED EXACTLY, A FIRE OR Combustible items may ignite, metallic items may become...
BASIC SPECIFICATIONS Minimum Clearances (cont.) Description 30” W. Models 36” W. Models 48” W. Models Rear - 0” with backguard or high shelf Overall width 29 7/8” (75.9 cm) 35 7/8” (91.1 cm) 47 7/8” (121.6 cm) 0” with island trim and non-combustible heat resistant rear wall Overall height Base Height Open Top Burners Sealed Top Burners...
PROXIMITY TO SIDE CABINET INSTALLATION 1. This range may be installed directly adjacent to existing 36” (91.4 cm) high base cabinets. IMPORTANT: The top WOOD/COMPOSITE OVERLAY INSTALLATION grate support MUST be 3/8” (.95 cm) above the adjacent base cabinet countertop. This may be accomplished by (Including Custom Ventilator Installation) raising the unit using the adjustment spindles on the legs.
GAS CONNECTION When installing or removing the range for service, a rolling lift jack should be used. Do not push against any of the All gas connections must be made according to national and local codes. This gas supply (service) line must be the edges of the range in an attempt to slide it into or out of the installation.
Page 6
GAS/ELECTRICAL CONNECTION DIAGRAM OVEN TUBULAR GAS BURNER ADJUSTMENT (See Illustration #1) Check the gas supply, and set the regulator to proper supply of gas. A properly adjusted burner should be stable and quiet. The flame should have a sharp, well defined blue inner cone with no yellow tipping. The flame should also be stable and uniform with no flames lifting off the burner ports.
SURFACE BURNER ADJUSTMENTS GRILL/GRIDDLE BURNER ADJUSTMENT 12” Grill Assembly 24” Grill Assembly (For Open Surface Burners) Grill (Illustration #) (See Illustration 2) 1. The grill burner orifice and air shutter are located beneath the front To gain access to the surface burner adjustments: end of the grill assembly.
Page 8
DSI SPARK MODULE SPECIFICATIONS Description of Operation (con’t) Lockout Power Requirements The control will lockout if any self-checks fail during normal operation. Also, the control will lockout if it failed to ignite Input Voltage range (L1-N) 102 to 132 VAC, 60/50 Hz 135 mA current typical gas after the selected number of ignition attempts or ignition recycles.
Page 9
When adjustments are required, contact your dealer/installer for corrections. If assistance is not available, contact Viking Range Corporation Preferred Service for the nearest authorized service agent at (888) 845-4641. All corrections to installation are the responsibility of the dealer/installer or end user.
Need help?
Do you have a question about the 30” W. Models and is the answer not in the manual?
Questions and answers