Optional Parts; Installation Work; Selecting An Installation Location; Installation Dimension - Fujitsu Ceiling Type Installation Manual

Indoor unit floor/ceiling type air conditioner
Table of Contents

Advertisement

Name and Shape
Q'ty
Operating Manual
1
Cover plate (left)
1
Screw (M4 × 10 mm)
2
Bracket (left)
1
For suspending the indoor unit
from ceiling
Special nut
4
For suspending the indoor unit
from ceiling
Screw (M4 × 20 mm)
6
For fi xing the wall bracket
Coupler heat insulator (Small)
1
For indoor side pipe
joint (Small pipe)
Cable-tie (Small)
2
For electrical wiring
Drain hose
1
Insulation (drain hose)
1
Adhesive type 100 × 220 (mm)
Remote controller
1
For air conditioner
operation
Remote controller
holder
1

2.4. Optional parts

Parts name
Wired remote controller
UTY-RNN*M
Simple Remote Controller
UTY-RSN*M
External connect kit
Wired remote controller is recommended using simultaneous twin or triple connection.
Name and Shape
Installation Manual
(This manual)
Cover plate (right)
Installation template
Positioning for under ceiling
type
Bracket (right)
For suspending the indoor unit
from ceiling
Wall bracket
For suspending the
indoor unit on the wall
Coupler heat insulator (Large)
For indoor side pipe joint (Large
pipe)
Cable-tie (Large)
For fi xing the drain hose
Wire clamper
For electrical wiring
Hose band
For installing drain
hose
VT wire
For fi xing the drain hose L
280 mm
Battery
For remote controller
Screw (M3 × 12 mm)
For remote controller holder
installation
Model No.
Summary
Unit control is performed by
wired remote controller
For air conditioner opera-
tion
UTY-XWZX
For control input/output port
Q'ty

3. INSTALLATION WORK

Especially, the installation place is very important for the split type air conditioner because
1
it is very diffi cult to move from place to place after the fi rst installation.

3.1. Selecting an installation location

Decide the mounting position together with the customer as follows.
1
Select installation locations that can properly support the weight of the indoor unit.
Install the units securely so that they do not topple or fall.
1
Do not install the indoor unit in the following areas:
Area with high salt content, such as at the seaside. It will deteriorate metal parts,
causing the parts to fall or the unit to leak water.
Area fi lled with mineral oil or containing a large amount of splashed oil or steam,
1
such as a kitchen. It will deteriorate plastic parts, causing the parts to fall or the unit
to leak water.
Area that generates substances that adversely affect the equipment, such as sulfu-
ric gas, chlorine gas, acid, or alkali. It will cause the copper pipes and brazed joints
to corrode, which can cause refrigerant leakage.
Area that can cause combustible gas to leak, contains suspended carbon fi bers or
fl ammable dust, or volatile infl ammables such as paint thinner or gasoline. If gas
2
leaks and settles around the unit, it can cause a fi re.
Area where animals may urinate on the unit or ammonia may be generated.
Do not install where there is the danger of combustible gas leakage.
Do not install the unit near a source of heat, steam, or fl ammable gas.
1
Install the indoor unit, outdoor unit, power supply cable, transmission cable, and
remote controller cable at least 1 m away from a television or radio receivers. The
purpose of this is to prevent TV reception interference or radio noise. (Even if they are
installed more than 1 m apart, you could still receive noise under some signal condi-
tions.)
If children under 10 years old may approach the unit, take preventive measures so that
1
they cannot reach the unit.
Take precautions to prevent the unit from falling.
(1)
Install the indoor unit on a place having a suffi cient strength so that it withstands
1
against the weight of the indoor unit.
(2)
The inlet and outlet ports should not be obstructed; the air should be able to blow all
over the room.
(3)
Leave the space required to service the air conditioner.
(4)
Install the unit where connection to the outdoor unit is easy.
(5)
Install the unit where the connection pipe can be easily installed.
1
(6)
Install the unit where the drain pipe can be easily installed.
(7)
Install the unit where noise and vibrations are not amplifi ed.
(8)
Take servicing, etc., into consideration and leave the spaces. Also install the unit
where the fi lter can be removed.
(9)
Do not install the unit where it will be exposed to direct sunlight.
1

3.2. Installation dimension

A. Floor type
2
Left
2
300
WARNING
CAUTION
Right
Unit : mm
300
En-2