8. Check of the counter.
The display shows an increasing number at intervals of 1 second.
This is a counter used by the board for its internal management.
9. Check of the temperature sensors.
The display shows one of the following codes:
Code
DESCRIPTION
E0
No error
E1
Evaporator sensor damaged
E2
Room temperature sensor damaged (installed on the display board)
E4
Room temperature sensor damaged (installed on the power board)
E5
0 degree compartment sensor damaged
Note:
The errors regarding the cooler and freezer air sensors are already displayed during the normal operation.
At this point all the phases necessary to chcek the loads have been displayed, therefore it is advisable to in-
terrupt the procedure of the SERVICE MODE unplugging and replugging the appliance.
Note:
If you do not want to interrupt the SERVICE MODE, the procedure continues with some phases dedicated ex-
clusively to the factory, therefore they must not to be considered.
Also in this case the exit from the SERVICE MODE is carried out unplugging and replugging the appliance.