10.1.4
Changing the settings of the various functions:
Holding the key pressed in for 2 seconds takes you to the user settings menu(LED at
the figure display start to flash). Pressing the key repeatedly results in a different function LED
flashing each time. When the LED is flashing the indicated function can be set with the
key . The value set is shown on the display.
The
on/off key closes the settings menu without storing the changes.
The reset
key closes the settings menu and the changes are stored.
If no key is pressed during a period of 30 seconds, the settings menu is closed automatically
and the changes are stored.
10.1.5
Maximum CH supply temperature
Press the key until the LED at
With the
and
key s set the temperature between 30°C and 90°C (default value 80°C).
10.1.6
DHW temperature
Press the key until the LED at
With the
and
keys set the temperature between 40°C and 65°C (default value 55°C).

10.2 Setting via the service code

The boiler controller in the appliance is factory set in accordance with the parameters.
These parameters can only be changed using the service code. Proceed as follows to activate
the program memory:
1.
Press the
and
keys simultaneously until a
display.
2.
Using the
and
keys set
3.
Using the
key set the parameter to be set on the service display.
4.
Using the
and
keys set the parameter to the desired value (visible) on the main
display.
5.
Once all desired changes have been entered, press the
the service display.
The boiler controller has now been reprogrammed.
Pressing the
key in takes you out of the menu without storing the parameter changes.
By pressing the
button over 5 seconds the default setting for the parameters will be restored. In the display "F-set" appears.

10.3 Parameters

Parameter
0
Service code [15]
1
Installation type
2
CH pump continuous
3
Maximum CH power set
3.
Max. power modulating pump
4
Maximum DHW power set
5
Min. supply temperature of the
heat curve
5.
Max. value flow temperature in
display (end user setting)
6
Min. outside temperature of the
heat curve
7
Max. outside temperature of
the heat curve
8
CH pump post purge period
Intergas Heating Ltd
starts to flash.
starts to flash.
0
appears on the service- and main
15
(service code) on the main display.
Combi Compact ECO RF
Factory settings
24
30
-
-
0
0
0
0
60
60
80
80
99
99
25
25
90
90
-7
-7
25
25
1
1
and
and
key until a
P
appears on
36
-
Access to installer settings
The service code must be entered (= 15)
0= Combi
0
1= Heating only + external DHW tank
2= DHW only (no heating system required)
3= Heating only
0
0= post purge period only
1= pump continuously active
2= pump continuously active with MIT switch
3= pump on with external switch
60
Adjustment range of set value parameter c up to 85%
Adjustment range of set value parameter c. up to 99%
80
99
Adjustment range of set value parameter d up to 99%
Adjustment range 10°C to 25°C
25
90
Adjustment range 30°C to 90°C
-7
Adjustment range -9°C to 10°C
25
Adjustment range 15°C to 30°C
1
Adjustment range 0 to 15 minutes