Network Error List - Konica Minolta bizhub C450 Network Scanner Operations

Network scanner
Hide thumbs Also See for bizhub C450:
Table of Contents

Advertisement

Scan function troubleshooting
6.2

Network error list

If a message appears when transmitting data over the network, take action
as described below.
Message
Memory overflow
Connection timeout
Server connection error
Login error
Specified folder not
found
Server disk full
Transmission error
Data size exceeded
C450
Cause and Corrective Action
The memory is full. Change the scan settings and scan again.
The connection to the server was disconnected. Login again or send
the data again.
Failed to connect to the server. Check the connection settings and
send the data again.
Failed to login to the server. Check the connection settings and send
the data again.
The specified folder for Scan to FTP or Scan to SMB does not exist.
Check the settings and send the data again.
The server disk is full. Free up some space on the disk such as by
contacting your server administrator.
Transmission failed. There may be problems with the line or config-
uration errors. Check the settings, wait awhile, and send the data
again.
The data could not be sent, because the data size specified on the
server was exceeded.
Check the conditions with your server administrator, change the
scan settings, and scan the document again.
6