Premier 8XP-W & 32XP-W Firmware The Premier IXP-W is only compatible with firmware version 1.3.4 and later of the Premier 8XP-W & 32XP-W. To check the firmware version of your receiver you can use either Ricochet Monitor software, or a Premier Engineers keypad.
Premier IXP-W Installation Manual 3. Quick Start Guide Firmware for the Premier 32XP-W & 8XP-W must be V1.3.4 or later for the Premier IXP-W to function Connect IXP-W to 8XP-W or 32XP-W 12V 0V T & R Connect 12V & 0V to control...
Premier IXP-W Installation Manual 4. System Overview 1: Address Switches Not Used. 2: Option Switches Only Switch 4 is used to enable/disable Walktest Mode, this is the same as on the receiver, please see INS467 for more information. 3: Global Poll Error Connect to a spare Zone on the control panel to signal a polling error from a device.
Page 6
Premier IXP-W Installation Manual 4: Global Tamper Connect to Global Tamper, or a spare circuit on the control panel to indicate Tamper on either a device, the IXP-W or the Receiver. 5: Global Low Battery Connect to a spare zone on the control panel to signal low battery from devices on the system. If not required link out.
Premier IXP-W Installation Manual Mounting the IXP-W Remove the Screw cover by locating the two small indents on the upper and lower edge with a small screwdriver, excessive force is not required. Remove the retaining screw INS538...
Premier IXP-W Installation Manual Wiring It is strongly recommended that the system is completely powered down (mains and battery) before wiring the expander and interface card. Connect the expander to the interface using 4-core cable, and make all other connections as follows:...
Premier IXP-W Installation Manual 5. Programming Option Switch Settings All switches on the IXP-W should be turned OFF. Option switch 2 on the Premier 8XP-W/32XP-W should be turned ON. Configuring Radio devices Up to 8 wireless devices of any combination can be learnt to the system. When learning devices the receiver needs to be in “commission mode”, please see INS467 for details.
Premier IXP-W Installation Manual 6. Specifications Electrical 10 - 13.7VDC Operating Voltage Current Consumption <20mA 4-wire standard 7/0.2 alarm cable up to 250m. Network Inputs 1 - 8 Boxed 176g unboxed 151g Weight L147mm x W92mm x H32mm Dimensions -10°C (+14°F) to +50°C (+122°F) Operating Temperature -20°C (-4°F) to +60°C (+140°F)
As a result the Premier IXP-W expander is covered by a two-year warranty against defects in material or workmanship. As the Premier IXP-W interface is not a complete alarm system but only a part thereof, Texecom cannot accept responsibility or liability for any damages whatsoever based on a claim that the Premier IXP-W interface failed to function correctly.
Texecom Limited, Bradwood Court, St. Crispin Way, Haslingden, Lancashire BB4 4PW, England. Technical Support: UK Customers Tel: 08456 300 600 (Calls charged at local rate from a BT landline. Calls from other networks may vary.) International Customers Tel: +44 1278 686197 Email: techsupport@texe.com...