Output and Overload Indicators
The output indicator light (green) will remain on during normal operating conditions.
If the generator is overloaded (in excess of 2.0 KW), or if there is a short in the connected
appliance, the output indicator light (green) will go out, the overload indicator light (red) will
illuminate and current to the connected appliance will be shut off.
Stop the engine if the overload indicator light (red) comes on and investigate the overload source
■ Before connecting an appliance to the generator, check that it is in good order and that its
electrical rating does not exceed that of the generator. Connect the power cord of the
appliance and start the engine.
OVERLOAD INDICATOR LIGHT (RED)
■ When an electric motor is started, both the overload indicator light (red) and the output
indicator light (green) may go on simultaneously. This is normal if the overload indicator light
(red) goes off after about four (4) seconds. If the overload indicator light (red) stays on,
consult your generator dealer.
OUTPUT INDICATOR LIGHT (GREEN)
20