Aim MyChron Light TG User Manual

Aim MyChron Light TG User Manual

Hide thumbs Also See for MyChron Light TG:

Advertisement

Quick Links

MyChron Light TG
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MyChron Light TG and is the answer not in the manual?

Questions and answers

Summary of Contents for Aim MyChron Light TG

  • Page 1 MyChron Light TG User Manual...
  • Page 2 User Manual Release 1.06 MyChron Light TG, the new AIM lap timer, is the evolution of the well known MyChron Light MCL. This new logger merges all functionalities and good qualities of its forefather with the new graphic display and adds a lot of other useful functions, like the visualisation of sampled data as histograms and the different working and sampling modes.
  • Page 3: Table Of Contents

      4.3 – Display setup ............................ 13   4.4 – System Information .......................... 13 Chapter 5 – How to change MyChron Light TG language ..........14   Chapter 6 – The memory and the data recall ..............16    ...
  • Page 4: Chapter 1 - Mychron Light Tg: Kits And Optional

    User Manual Release 1.06 Chapter 1 – MyChron Light TG: kits and optional MyChron Light TG is available in four different kits depending if internally or externally powered. 1.1 – MyChron Light TG with internal power kit MyChron Light TG with internal power basic kit: code X04MYC40TGST •...
  • Page 5: Mychron Light Tg With External Power Kit

    • Infrared receiver for lap times detection (6) • User manual (3) • Infrared transmitter with external power cable (4) Please note: MyChron Light TG with external power has a blue backlight that cannot be disabled. 1.3 – Optional to MyChron Light TG kits •...
  • Page 6: Chapter 2 - Installation And Powering

    4 Silent Block not included in the kit. MyChron Light TG is powered by two 3 Volts round batteries type CR 2430 included in the infrared receiver. To change the batteries see the chapter concerning MyChron Light TG maintenance.
  • Page 7: How To Install And Power The Infrared Receiver

    The receiver is powered like the system. 2.4 – The lap transmitter: installation, powering, working mode AIM produces and sells two kind of transmitters: the lap transmitter (image below on the left) and the split transmitter (below on the right). The two devices emits different signals and MyChron Light TG can distinguish and manage them.
  • Page 8: How To Change Mychron Light Tg Batteries

    The simplest way to record correct lap times is to use the same transmitter(s) for all drivers. Use obscuring time function (paragraph 3.2) to be sure that MyChron Light TG reads only the desired transmitter(s).
  • Page 9: Chapter 3 - Mychron Light Tg Quick Configuration

    Release 1.06 Chapter 3 – MyChron Light TG quick configuration MyChron Light TG needs to be configured. Here follows explanation of the steps to be performed for a quick configuration. Other configuration options are deepened after. Here below is MyChron Light TG keyboard. Functions associated are shown by the display in correspondence to each button.
  • Page 10: Session Mode

    MyChron Light TG User Manual Release 1.06 3.2 – Session mode From the main menu select “Session mode”. The related menu is shown here below. Available options are: • Lap Counter: the lap timer is set as lap counter; • Qualify: fill in the session duration in minutes (range from 5 to 60);...
  • Page 11: Split Times Visualisation

    From the main menu select “Configuration”. The related page is shown here below. Select “Split”. The related under menu shows all possible split visualisation modes. MyChron Light TG offers eight different split visualisation modes: • None: records splits but do not show them;...
  • Page 12: What Shows The Display When A Lap Or A Split Time Is Recorded

    MyChron Light TG User Manual Release 1.06 3.4.2 – What shows the display when a lap or a split time is recorded. No matter what split visualisation mode is set, when the logger records a lap or a split time it shows different data.
  • Page 13: Chapter 4 - Other Configuration Function

    MyChron Light TG User Manual Release 1.06 Chapter 4 – Other configuration function Additional to the quick configuration parameters MyChron Light TG offers a lot of other configuration function. From the main menu select “Configure”. This menu appears. 4.1 – Set Time/Date From configuration menu select this voice ant the related menu appears.
  • Page 14: Display Setup

    From configuration menu select this voice and the related page appears. The display shows: • on top the logger name (AIM MyChron TG); • central on the display firmware version actually installed on the logger (V 19.16); • bottom logger serial number (S.N. 0000014050).
  • Page 15: Chapter 5 - How To Change Mychron Light Tg Language

    Release 1.06 Chapter 5 – How to change MyChron Light TG language MyChron Light TG can show menus in different languages. To modify the language it is necessary to perform a firmware upgrade. Visit www.aim-sportline.com, download firmware area, download the last available firmware version and run it.
  • Page 16 MyChron Light TG User Manual Release 1.06 The system starts upgrading the firmware. In case the logger firmware is already updated the system shows the message here on the right. Since the language can be changed only through this procedure press “Yes”.
  • Page 17: Chapter 6 - The Memory And The Data Recall

    Release 1.06 Chapter 6 – The memory and the data recall MyChron Light TG can store up to 2000 laps and has a round memory: when lap number 2001 is stored the first one is deleted and so on. Once the session is over it is possible to recall stored data on MyChron Light TG display pressing “MEM”...
  • Page 18: What Is "Best Rolling" And "Theoretical Best

    MyChron Light TG User Manual Release 1.06 6.1 – What is “Best Rolling” and “Theoretical best” Time Start/Finish Time Time Split 2- Lap Time Number line-Split 1 Split 1-Split 2 Start/Finish line 1’23” 30” 18” 35” 1’22” 28” 20” 34”...
  • Page 19: Capitolo 7 - Software, Driver, Data Download And Maintenance

    (optional – code X04MYC40PC00). USB input is covered by a rubber cap on the left side of the logger. Please note: for the PC to see MyChron Light TG it is necessary to have data stored in the logger memory.
  • Page 20: Tg Picture Manager Software

    7.2 – TG Picture Manager software TG Picture Manager – available only in English – allows to: • upload some images .bmp 128*64 pixel format on MyChron Light TG to be used also as screensaver. The software converts each image in greyscale and makes it possible to manage the black threshold;...
  • Page 21: Chapter 8 - Technical Notes

    MyChron Light TG User Manual Release 1.06 Chapter 8 – Technical notes Here below are MyChron Light TG dimensions in cm (pixel). 22.47 (0.9) 61.6 (2.42) 19.1 (0.75) 78.1 (3.07) General Characteristics: Internal power: 2 3V round batteries code CR2430...

Table of Contents