4 - 52 CS4070 Scanner Product Reference Guide
CLSI Editing
Parameter # 54
Enable this parameter to strip the start and stop characters and insert a space after the first, fifth, and tenth
characters of a 14-character Codabar symbol. Enable this feature if the host system requires this data format.
NOTE Symbol length does not include start and stop characters.
Enable CLSI Editing
NOTIS Editing
Parameter # 55
Enable this parameter to strip the start and stop characters from a decoded Codabar symbol. Enable this
feature if the host system requires this data format.
Enable NOTIS Editing
(1)
(1)
*
Disable CLSI Editing
(0)
*
Disable NOTIS Editing
(0)