Indesit Company HEALTH AND SAFETY For the servicing of refrigeration products, containing Isobutane R600a refrigerant. These instructions are in addition to any other Company procedures already published. Published primarily for Indesit Company engineers working in the UK or Southern Ireland, for which these instructions are MANDATORY.
Page 3
Indesit Company HEALTH AND SAFETY 19. Working with a naked flame i.e. soldering or brazing is forbidden. Unless otherwise stated, pipework connections must only be made using the Lokring coupling system. 20. Electronic leak detectors with high voltage tips must NOT be used with any Isobutane (R600a). 21.
Indesit Company CONTENTS Health and Safety ............2 - 3 Index &...
Page 5
Indesit Company MODEL VERSION IDENTIFICATION The models included in this publication are 1870 & 2000 mm high no-frost fridge freezers that were introduced in Jan 2008. There are two versions of the above range of models that share the same model number and commercial code.
Page 6
Indesit Company MODEL INTRODUCTION All models are similar with regard to the furniture design, but there are variations for energy consumption and exterior colour. Model FF187E interior: The interior of the fridge has glass shelves, chromed steel wine rack and two salad bins with a glass cover. The door has a bottle shelf with retainer, dairy shelf with a lid and one commodity shelf.
Company SPECIFICATIONS Colour Polar - P Graphite - G Aluminium - A Stainless Steel Black - K Introduction (inox) - X Date FF187EP FF187EG FF187EA Jan 2008 FF200EP FF200EG FF200EA FF200EX FF187EPL FF187EK May 2008 FF200EPL FF200EK GENERAL: Manufactured in:...
Page 8
Indesit Company TECHNICAL DATA: Power Supply Voltage: 220/240 V Power Supply Frequency: 50 Hz Absorbed Power: 180 W Absorbed Current: 0.5 A Ω COMPRESSOR WINDINGS FF187E FF200E Manufacturer: Jiaxipera Tecumseh Type I/D: ZBT1114CY TWB1370MJS Winding Resistances: 16.0 Ω 26.75 Ω Start: 13.3 Ω...
Indesit Company DESCRIPTION OF APPLIANCE Detailed View Control panel LAMP Removable lidded shelf with EGG TRAY SHELVES** Removable multipurpose SHELF** WINE RACK* FRESH BOX BOTTLE shelf Compartment FF200E models only FRUIT and VEGETABE bin** FF187E models have two half bins FREEZER and STORAGE compartment ICE CARE ice tray**...
Page 10
Indesit Company DESCRIPTION OF APPLIANCE: POWER Indicator light REFRIGERATOR FREEZER SUPER FREEZE SUPER COOL OPERATION OPERATION Indicator light Indicator light Knob Knob SUPER COOL SUPER FREEZE Button Button The SUPER COOL (quick cool) function lowers The SUPER FREEZE (fast freeze) function the temperature of the refrigerator compartment allows the freezing of fresh food.
Indesit Company COMPONENT FUNCTION General Information The power module is made up of a number of smaller individual modules (sections), each one controlling a functional component. The modules are linked together when required to control a particular function or functions. The linking of the individual modules is optional and therefore allows for each module to be switched ON or OFF, this is determined from the data stored or collected by the modules and the results of module comparisons.
Indesit Company Compressor The compressor is managed by the power module and switches on whenever a demand for cooling is received. There are situations of cooling demand in which the compressor remains off. These are as follows: Compressor protection: the compressor switches on once a minimum safety time lag has elapsed since the last power-off, thereby allowing the refrigerant gas pressure to reach a point of equilibrium in the refrigerant circuit.
Indesit Company AUTO-TEST This helps with a quick check of the loads and sensors (thermistors), which otherwise are difficult to activate. NOTE: - Before using the AUTO-TEST it is advisable to check the correct operation of the Mains (Green), Super Cool and Super Freeze (Amber) LEDs and the fridge interior lamps, which are used for signalling possible malfunctions.
Page 14
Indesit Company FAULT CONDITIONS POWER Indicator light REFRIGERATOR FREEZER SUPER FREEZE SUPER COOL OPERATION OPERATION Indicator light Indicator light Knob Knob SUPER COOL SUPER FREEZE Button Button Alarm Conditions: are signalled to the user by flashing LEDs and accompanied by an audible beep. Fault Conditions: are signalled to the engineer during an Auto -Test by flashing LEDs with NO audible beep.
Indesit Company EXPLANATION OF AUTO-TEST CODES (The fault codes below are generic and also associate with other models not listed in this manual) FAULT CAUSE CORRECTIVE ACTION CODE • Check for moisture on module, check connections especially on connector E1; •...
Page 16
Indesit Company EXPLANATION OF AUTO-TEST CODES (The fault codes below are generic and also associate with other models not listed in this manual) FAULT CAUSE CORRECTIVE ACTION CODE • Check module connector E1; • Check resistance reading between pins 2 and 6 of connector E1;...
Page 17
Indesit Company • Check module connector E4; • Check NTC sensor, ensuring that the values read between pins 1 and 2 of Freezer evaporator NTC sensor connector E4 is compatible with the values F 25 open / short circuit in the “Sensor Resistance Table” on page 34, (also heat the sensor by holding it with your hand / fingers where possible and check the change in the resistance value);...
Indesit Company AIR FLOW Shown through a schematic section of the cabinet WHEN THE DAMPER (BAFFLE) OPENS, COLD AIR ENTERS THE FRIDGE VIA THE INLET PORTS IN THE MULTI-FLOW UNIT. NOTE: SOME PORTS ARE INTENSIONALLY BLOCKED OFF. WHEN THE DAMPER (BAFFLE) OPENS, AIR RETURNS TO THE FREEZER SECTION VIA THE EXHAUST GRILLE IN THE CENTRE OF THE MULTI-FLOW...
Indesit Company DUCT PANEL AIR FLOW (Exploded View) REAR SECTION REAR SECTION FRONT SECTION FRONT SECTION = THE EVAPORATOR FAN DRAWS AIR UNDER AND BEHIND THE REAR DUCT PANEL AND THROUGH THE EVAPORATOR ASSEMBLY. IT IS THEN BLOWN BETWEEN THE FRONT AND REAR DUCT PANELS. = AIR FLOW IS THEN CHANNELLED AND DISTRIBUTED UNIFORMALLY TO THE OUTLET PORTS OF THE FRONT AIR DUCT.
Indesit Company POWER / CONTROL MODULE Parameters (Values stated are for guidance only - may change without notice) Parameters set in the module memory control the appliance functions. The minimum and maximum values for temperature are preset in the module memory. Sensors monitor temperature and the values are registered in the module.
Page 21
Indesit Company POWER/CONTROL MODULE Parameters (Values stated are for guidance only - may change without notice) DEFROST AND DRIP TRAY HEATING ELEMENTS • Compressor ON time since the last defrost cycle. Defrost and Drip Tray Heating 600 minutes Elements - •...
Indesit Company FAULT DIAGNOSIS QUICK GUIDE SYMPTOM CAUSE ACTION • Close fridge door. • Indicates that the fridge door has INTERIOR • Check the magnet position in the top been left open for too long a period, LIGHT of the fridge door cover strip. (over 2 minutes approx.).
Page 23
Indesit Company FAULT DIAGNOSIS QUICK GUIDE SYMPTOM CAUSE ACTION • Freezer evaporator and air • If the freezer temperature is OK then temperature are correct. advise the customer that the compressor will start when there is a demand for cooling. •...
Indesit Company SERVICING & DISMANTLING INSTRUCTIONS Important Notes for Guidance: Before commencing any work refer to the Safety Notes at the beginning of this manual. A. Removing the Fridge Door Remove the contents, food and furniture. Remove the top hinge blanking plug from the top of the fridge door and unclip the door hinge cover magnet strip.
Page 25
Indesit Company Remove the plastic cover from the interior lamp housing. Unscrew the screws at base of multiflow unit and from the inside of the lamp holder. Pull the base of the multi-flow unit towards you while simultaneously sliding it downwards releasing it from the top locating lugs.
Indesit Company PROGRAMMING THE POWER MODULE The replacement power module is supplied un-programmed as it is used on other model with their own specific programmes. The use of an Eeprom is no longer necessary. The module does not have this component and there is no Eeprom socket for inserting it.
Page 27
Indesit Company PROGRAMMING METHODS EXPLAINED: METHOD 1 - Indesit ENGINEERS ONLY If the Power Module has been replaced it will require programming using the following method. The module can be programmed via a Hand-Held (Emit), using a USB lead (Part No. C00222800), Black Hardware key (Part No.
Page 28
Indesit Company PROGRAMMING METHODS EXPLAINED METHOD 2 - SMARTCARD - SUITABLY QUALIFIED PERSONS ONLY If the Power Module has been replaced, it will require programming using the following method. 1. Disconnect the appliance from the electricity supply. 2. Connect the Low End Adaptor version 2007 to the module. (See “Connecting the Low End Adaptor”...
Page 29
SMARTCARD PROGRAMMING PROCEDURE - FLOWCHART START DISCONNECT THE SMARTCARD READER FROM THE DISCONNECT (unplug) THE APPLIANCE FROM THE ELECTRICAL SUPPLY (grid) APPLIANCE AND THE SMARTCARD FROM THE SMARTCARD READER AND ACTION BELOW: LED was flashing SLOWLY, and a INSERT A VALID SMARTCARD, RELATING TO THE MODEL & MAIN POWER If the smartcard was inserted, check for the following: MODULE (board) TO BE PROGRAMMED, INTO THE SMARTCARD READER...
Page 30
Indesit Company CONNECTING THE LOW END ADAPTOR - 2007 Version The photos below may show a differnet model to the one you are programming but the Low End Adaptor connection is the same. BEFORE PROCEEDING UNPLUG THE APPLIANCE FROM THE ELECTRICITY SUPPLY Photo 1 Step 1 - Lower the control panel to...
Indesit Company WIRING CONNECTION CHART DEFROST HEATER DEFROST HEATER ALTERNATIVE DEFROST HEATER THERMAL FUSE THERMAL FUSE CONNECTION PLUG CONNECTION PLUG THERMAL FUSE (FRONT VIEW – PIN SIDE) (REAR VIEW – WIRE SIDE) CONNECTION PLUG (REAR VIEW – WIRE SIDE) THERMAL FUSE (CLIPPED TO EVAPORATOR) WHITE Freezer Evaporator Fan Motor...
Page 32
Indesit Company POWER / CONTROL MODULE EDGE CONNECTIONS E 1 – TERMINAL CONNECTIONS TERMINAL WIRE COLOUR COMPONENT BROWN LINE (LIVE) BLACK COMPRESSOR OVERLOAD (COMMON) WHITE EVAPORATOR FAN MOTOR BLUE NEUTRAL GREY THERMAL FUSE NOT USED FRIDGE INTERIOR LAMP ORANGE YELLOW FRIDGE INTERIOR LAMP THERMAL FUSE WHITE...
THEORETICAL WIRING DIAGRAM SOLDERED SIDE POWER CONTROL MODULE FLY LEAD/HARNESS TO COMPRESSOR COMPARTMENT. THIS HARNESS IS FOR PRODUCTION USE ONLY. DO NOT CONNECT OR USE THE FLY END OF THIS HARNESS FRIDGE DAMPER (baffle) FRIDGE INTERIOR LAMP FREEZER EVAPORATOR SENSOR EVAPORATOR FAN MOTOR FRIDGE AIR SENSOR...
Indesit Company THERMISTOR SENSOR LOCATIONS Three sensors are used in these models, the approximate position is as follows: - 1. Freezer Air Sensor - Located on the compressor step, behind the duct mounting on the right. 2. Freezer Evaporator Sensor - Located in the top right corner of the freezer evaporator. 3.
Indesit Company DOOR REVERSAL Important Notes for Guidance: Before commencing any work refer to the Safety Notes at the beginning of this manual. Read the instructions below fully and refer to the diagrams on the right before carrying out the door reversal. Note: Before commencing the door reversal, you will require the left door stops and centre hinge blanking plugs normally supplied loose with the literature pack that comes with the appliance.
Page 36
Indesit Company Service Manual UK English 36 of 36...