12.11
nanoe-G Operation
•
This operation provides clean air by producing great amount of negative ions and distribute through the
discharge airflow to capture or deactivate moulds, bacteria or viruses.
•
nanoe-G operation start condition
During unit running at any operation mode, if nanoe-G operation is activated, combination operation
o
(operation mode + nanoe-G operation) starts.
During unit is OFF, if nanoe-G operation is activated, nanoe-G individual operation starts.
o
•
nanoe-G operation stop condition
When OFF/ON button is pressed to stop the operation.
o
When nanoe-G button is pressed.
o
When OFF Timer activates.
o
•
nanoe-G operation pause condition
When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoe-G operation resume after
o
indoor fan restarts.
When indoor intake temperature ≥ 40°C. nanoe-G operation resume after indoor intake temperature ≤ 40°C
o
continuously for 30 minutes.
•
Indoor fan control
During any operation mode combines with nanoe-G operation, fan speed follows respective operation mode.
o
However, nanoe-G system enabled when fan speed ≥ 500rpm to ensure proper negative ion distribution,
nanoe-G system disabled when fan speed < 500 rpm.
During nanoe-G individual operation, only Auto Fan Speed and no Powerful operation is allowed. Even if Fan
o
Speed button is pressed, no signal is sent to the unit and no change on remote control display. Auto Fan
Speed for nanoe-G operation changes from SHi to Hi after 4 hours of operation.
•
Airflow direction control
During any operation mode combines with nanoe-G operation, airflow direction follows respective operation
o
mode.
During nanoe-G individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, no
o
signal is sent to the unit and no change on remote control display.
•
Timer control
When ON Timer activates when unit stops, previous operation resumes and restored last saved nanoe-G
o
operation status.
When ON Timer activates during any operation, no change on current operation.
o
When OFF Timer activates during any operation, all operation stops and the latest nanoe-G operation status
o
is saved.
•
Indicator
When nanoe-G starts, nanoe-G indicator ON.
o
•
Remote control receiving sound
Normal operation
o
Nanoe-G operation
o
Stop
o
Nanoe-G individual operation
o
•
Power failure
During nanoe-G individual operation, if power failure occurs, after power resumes, nanoe-G individual
o
operation resumes immediately.
During combination operation, if power failure occurs, after power resumes, combination operation resume
o
immediately.
nanoe-G operation
Normal operation
nanoe-G individual operation : Beep
Stop
40
: Beep
: Beep
: Long Beep