NEC Univerge SV8100 Features And Specifications Manual page 503

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program
Program Name
Number
14-01-13
Basic Trunk Data Setup –
Trunk-to-Trunk Transfer
20-01-05
System Options – DTMF Receive
Active Time
20-06-01
Class of Service for Extensions
20-09-01
Class of Service Options
(Incoming Call Service) –
Second Call for DID/DISA/DIL/
E&M Override
20-13-23
Class of Service Options
(Supplementary Service) –
Display the Reason for Transfer
20-14-01
Class of Service Options for
DISA/E&M – First Digit
Absorption (Delete First Digit
Dialed)
Direct Inward System Access (DISA)
Description/Comments
If DISA caller can place outgoing
calls through the system (refer to
Program 20-14 in the Electra Elite
IPK II Programming Manual),
Enable loop supervision for the
DISA trunk. If DISA caller cannot
use the system trunks for outgoing
calls, enter Disable.
After answering the call, the
system attaches a DTMF receiver
to the DISA trunk for this time.
Assign a Class of Service (1~15)
to an extension.
Turn Off or On an extension ability
to receive a second call from a
DID, DISA, DIL, or tie line caller.
With this option set to 1, the
destination extension must
be busy for a second DNIS
caller to ring through. If the
destination extension does
not have a trunk or CAP key
available for the second call
and a previous call is ringing
the extension but has not yet
been answered, the second
caller hears busy regardless
of this program setting.
Select whether or not an extension
should display the reason a call is
being transferred to their
extension (Call Forward Busy, Call
Forward No Answer, DND).
For tie lines, enable/disable the
ability to ignore the first incoming
digit. Use this to make the tie trunk
compatible with 3- and 4-digit tie
line service. This option does not
apply to DISA.
Assigned Data
1
0 = Disable
1 = Enable
(default = 1)
0~64800 (seconds)
(default = 10)
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port
= Class 1
0 = Off
1 = On
(default = 1 for
COS 1~15)
0 = Off
1 = On
(default = 0 for
COS 1~15)
0 = Off
1 = On
(default = 0 for
COS 1~15)
Issue 13.0