Time Guard SLFM360 Installation & Operating Instructions Manual

Time Guard SLFM360 Installation & Operating Instructions Manual

360º flush mount ceiling pir light controller

Advertisement

Quick Links

360º FLUSH MOUNT
CEILING PIR LIGHT
CONTROLLER
Cat No. SLFM360

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLFM360 and is the answer not in the manual?

Questions and answers

Shirley Boardman
January 19, 2025

Is the time guard slfm360N the same as slfm360N

Summary of Contents for Time Guard SLFM360

  • Page 1 360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER Cat No. SLFM360...
  • Page 2 Introduction The SLFM360 utilises passive infrared technology to detect heat radiation of moving human bodies.Upon detection, the attached lighting load will illuminate for a user-determined time period. An integral daylight sensor ensures all day or night-only operation. Important Information: Light Pollution and...
  • Page 3 Factory fitted bridge wire REMOVED Time On Lux - setting Dusk/Dawn setting Levering area Switched Mains Factory fitted Load Supply bridge wire L N E In the above illustration: - the L1 L2 terminals are used to control a DC load or if the load uses a different phase or voltage supply from the AC mains in.
  • Page 4: Parts Included

    Parts included • PIR Sensor unit. • Instruction manual. Please keep safe for future reference. • Accessory Pack. Includes wiring cover, 2 x cable clamps, 4 x clamp screws and 1 x lens mask sticker. Tools and parts needed • 3 core flexible cable. •...
  • Page 5: Installation

    optimum height of 2.5m. Careful positioning of the sensor will be required to ensure optimum performance. See diagram A detailing detection range and direction. The sensor is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS (see diagram B).
  • Page 6 off when not required or for maintenance purposes and allows it to be conveniently brought into manual override. Remove the wiring cover from the sensor by depressing the catch on the side and lifting it clear of the twin locators opposite the catch (see diagram G). Mark the position of the 75mm diameter locating hole centre taking care to avoid ceiling joists and other obstructions within the 75mm diameter.
  • Page 7 Push back the locating springs (diagram E) and feed the unit into the ceiling void via the 75mm hole. The locating springs will now fold back and hold the SLFM360 in place. Setting up Walk Test Procedure TIME - Fully anti-clockwise...
  • Page 8 Masking the Sensor Lens To reduce the sensor coverage, preventing detection in unwanted areas, mask the sensor lens using the lens mask sticker supplied (see diagram C). For your information, the centre section of the lens covers short range detection, and the outer edge of the lens covers long range.
  • Page 9 to operate too early (ie. when it is quite light), adjust the control slightly anti-clockwise. If the unit starts to operate too late (ie. dusk), adjust the control slightly clockwise. Continue to adjust until the unit operates as desired. Once the unit is set up as desired, ease the unit back into position under spring pressure.
  • Page 10: Troubleshooting Guide

    Troubleshooting guide Problem Solution Cover PIR lens with a thick cloth. If the • Lamp stays ON all the light turns out, check detection area for time at heat or reflective source. night. If the light stays on, check wiring. See Section 3.
  • Page 11: Technical Specifications

    Technical specifications Up to 6 metres diameter Detection Range: (3m Radius) at mounting height of 2.5m 360º Detection Angle: Power Supply: 230 V AC ~ 50Hz 2000W (e.g.20 x 100W GLS) Maximum Switchable Load: Incandescent/filament or 500W Fluorescent/low energy lighting. Not suitable for discharge lighting.
  • Page 12: Year Guarantee

    3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515.