5.
5.2.4
Description of steps with modes:
Step 00: Display of mask version number
After activating the service test program, step 00 and the
mask version number are automatically displayed.
Product ID. No.
The mode can be left again by pressing the SELECT key on
the remote control. The currently selected position number
appears and flashes on the display.
A step between 00 and 99 can now be selected
Step 01: Checking the drive positions
By pressing the SELECT key whilst Step 01 is flashing, the
drive position appears on the display.
The FTA signal from the photoelectric barriers which controls
the revolutions of the loading motor is used to check the drive
condition.
The drive position is shown as a 3-digit decimal number by
counting the FTA pulses on the display.
(e.g. 213 = Play)
Table of drive positions:
Status
Position
(FTA dec)
Eject
007 +2/-2
Index
191 +0/-2
Stop
200 +4/-4
Play
213 +4/-4
Reverse
237 +2/-0
Function of the Init switch:
The diagram shows the function of the Init switch, depending
on the position of the deck. The number of FTA pulses is
important for the position of the drive.
VR120
Service modes, Repair tips
Central control
Build No.
mask No.
A: DC, 2 V/Div, 0.5 s/Div
B: DC, 2 V/Div, 0.5 s/Div
A
B
Eject
I n d e x /
w i n d - r e w i n d
Cass down
Step 02: Display of the deck error codes
By pressing the SELECT key whilst Step 02 is flashing, the
deck error code is shown on the display.
Checking the drive function Loading and unloading time
The signal (FTA) of the photoelectric barrier which controls
the revolutions of the loading motor is used as a reference for
the loading and unloading time.
Stopping of supply or take-up reels
The tacho signals of the left (WTL) and right (WTR) winding
disks are used as control reference.
Stopping of head drum motor
This is monitored with the PG/FG signal. The signal is
discharged from the e.m.f. of the non-conducting spools of
the head cylinder motor, showing the position of the head
cylinder.
Capstan motor fault
This is monitored with the FGD signal.
If one of the above sensor signals is not available, the
recorder tries to put the lift into the "EJECT" position.
Explanation of deck error codes and deck error status
The last error code is stored and remains in the EEPROM,
even if the recorder is disconnected from the mains.
The error code can be erased by pushing the CLEAR button
on the remote control.
The display shows, for instance:
The left digit shows the error:
(e.g.: Error 2 = Capstan error)
Init switch
FTA pulses
Play