AntiFreeze

This feature allows you to set a speed (1100 RPM -3450 RPM) that will run when the IntelliFlo
VS+SVRS Pump goes into anti freeze mode. The temperature level that you wish anti freeze mode to
start can also be set.
IMPORTANT NOTE: This feature is for protection of the pump. It should not be depended upon for
freeze protection of the pool. Certain situations could cause the pump to sense a different temperature
than actual air temperature. Your automation systems air temperature sensor should be used to sense
actual temperature. For example, if the pump is located indoors, the temperature of the room does not
indicate the outdoor temperature. The pump does not sense the water temperature.
To access the AntiFreeze menu:
1. Check that the green power LED is on.
2. Press the Menu button. "Settings" is displayed.
3. Use the Down arrow button to scroll to "AntiFreeze".
4. Press the Select button. The factory default is AntiFreeze "Enabled".
5. To disable AntiFreeze. Press the Select button, "Enabled" will highlight.
6. Use the Up arrow button. "Disabled" is displayed.
7. Press the Enter button.
To program AntiFreeze when enabled:
8. Press the Down arrow button.
9. Press the Select button to change the setting. The cursor will highlight the first column
(ones).
10. Use the Up or Down arrow button to select 1100 - 3450 RPM.
11. Press the Enter button to save the setting.
12. Press the Down arrow button. "Pump Temperature" is displayed.
pump will activate AntiFreeze. The factory default is 40° F (4.4° C).
13. Press the Select button to change the setting. The cursor will highlight the first column
(ones).
This setting can be changed from 40° F to 50° F (4.4° C - 10° C).
14. Press the Enter button to save the setting.
Note: To cancel any changes, press the Escape button to exit without saving.
15. Press the Escape button to exit.
INTELLIFLO
VS+SVRS and INTELLIPRO
®
"Set Speed" is displayed. The factory default is 1100 RPM.
VS+SVRS Variable Speed Pump Installation and User's Guide
®
This is the temperature the
®

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the INTELLIFLO VS+SVRS and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Intellipro vs+svrs

Table of Contents

Save PDF