S 3Xx; S 4Xx; Figure 5-35: S 4Xx Motor With Holding Bracket - Miele S 247i Technical Manual

Table of Contents

Advertisement

Technical Information
5.18.3

S 3xx

The motor is installed in the cap assembly.
1. Remove the cap assembly (Section 5.6).
2. Remove the Phillips screw securing the motor.
3. Ease open the group plug retaining lug and disconnect the plug.
4. Lift the motor at the rear and remove it.
5. Remove the motor holder and seal.
Reinstalling:
1. Install the holder with seal on the motor.
2. Ensure that the motor seal is positioned correctly.
3. Reinstall the motor in the rear casing.
5.18.4

S 4xx

Motor with holding bracket:
1. Unscrew the rear casing (Section 5.7).
2. After lifting the rear casing, the holding bracket (Figure 5-35, Item 1) can
be removed, thus releasing the motor.

Figure 5-35: S 4xx Motor with Holding Bracket

Motor with central bearing:
1. Unscrew the rear casing (Section 5.7).
2. Unclip and release the central bearing (Figure 5-36, Item 1) from the rear
casing.
3. Unscrew the motor holder (Figure 5-36, Item 2) if necessary and remove
the motor.
4. If a holding bracket is also present as in Figure 5-35 then it should also be
removed.
S 2xx, S 3xx & S 4xx Canister Vacuums
50

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S 234iS 270iS 278iS 280iS 348i

Table of Contents