1-5-4 Developer section
(1) Detaching and refitting the developer unit
Procedure
1. Open the top cover.
2. Release the lock lever by rotating and
then remove the toner container.
3. Open the front cover.
4. Pull the imaging unit forward.
5. Release the hook and then remove the
container guide by sliding backwards.
Top cover
Toner container
Container
guide
Hook
Front cover
Imaging unit
1-5-13
2LV/2L1/2L2/2MS/2MT
Lock lever
Figure 1-5-20
Top cover
Figure 1-5-21
Need help?