Trouble Shooting - Response SL2 Installation & Operating Manual

Wireless security alarm
Table of Contents

Advertisement

TROUBLE SHOOTING

Symptom / Recommendation
Siren immediately sounds when system
armed.
1. Siren tamper switch activated - adjust tamper
plunger and ensure that switch fully closes when
Siren is mounted. If the wall is excessively
uneven, the Siren may need relocating to a
more suitable position.
Siren sounds when system is disarmed or
has not been triggered by an intruder.
1. Detector tamper switch activated - check that
the battery covers of all Detectors and Keypads
to ensure they are securely and fully fitted.
2. Personal Attack Alarm operated from a Remote
Control or Keypad.
3. Jamming Detection circuit operation (see page 11).
4. Detector giving false alarm signals, see below.
Siren not responding to Detector.
1. Siren is in Service Mode - switch to operating
Mode (see page 19).
2. Detector battery low - Replace battery.
3. Ensure 'ID code' of the Detector has been learnt
by the Siren (see page 18).
4. Ensure Detector is within effective radio range
of Siren and equipment is not mounted close to
metal objects.
Siren not responding to Remote Control
or Keypad.
1. Siren is in Service Mode - switch to operating
Mode (see page 19).
2. Remote Control or Keypad battery low
- Replace battery.
3. Ensure 'ID code' of the Detector has been learnt
by the Siren (see page 18).
4. Incorrect User Access Code being entered at
Keypad.
5. Siren rechargeable battery discharged:
a. Clean Solar Panel.
b. Check age of rechargeable battery - replace
if at end of useful life.
c. Fit new initial power-up battery and re-power
up Siren.
6. System locked - Reset system:
a. Disconnect Siren rechargeable and initial
power-up batteries.
b. Cover Solar Panel with lightproof material
and leave system for 5 minutes.
c. Reconnect batteries and then remove Solar
panel cover and take out of Service Mode.
LED on Remote Control not illuminating, or
is dim when unit is operated.
1. Ensure battery is fitted with correct polarity.
2. Ensure battery holder connections are making
good contact with the battery.
3. Battery low - replace battery.
Keypad not operating (
illuminate).
1. Incorrect User Access Code being entered.
2. Battery missing.
PIR Movement Detector false alarming.
1. Ensure that the detector is not pointing at a
source of heat or a moving object.
2. Ensure that the detector is not mounted above a
radiator or heater.
3. Ensure that the detector is not facing a window
or in direct sunlight.
4. Ensure that the detector is not in a draughty area.
5. Sensitivity set too HIGH - reset to LOW
sensitivity, (i.e. SW3 to down position).
light does not
25

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SL2 and is the answer not in the manual?

Questions and answers

Barry Griffitbs
February 13, 2025

alarm does not bleep after setting alam or after deactivating alarm

1 comments:
Mr. Anderson
February 13, 2025

The Response SL2 alarm may not bleep after setting or deactivating the alarm if it is in Service Mode, as the siren does not operate in this mode until a remote control or keypad is linked to it. Additionally, if the Alarm Lockout feature has been activated after three alarm triggers, the system will prevent further re-arming and responses. Another possible reason is a low battery status, as the system incorporates battery level monitoring, and depleted batteries may affect functionality.

This answer is automatically generated

Akhtar khalil
March 5, 2025

I need sl2 keypad my is broken

Akhtar khalil
March 18, 2025

My keypad is not working I need help

1 comments:
Mr. Anderson
March 18, 2025

To fix a non-working keypad on a Response SL2, follow these steps:

1. Check the Battery: Ensure the PP3 Alkaline battery is installed and not depleted. If the "LOW BATT" LED is flashing, replace the battery.

2. Press Keys Firmly: When using the keypad, press the buttons firmly and within 5 seconds of each other.

3. Verify User Access Code: Ensure the correct User Access Code is entered. If incorrect, wait 10 seconds before retrying.

4. Reset to Factory Defaults (if necessary):
- Remove the battery.
- Press and hold any key for more than 1 second.
- Set the jumper link according to the manual.
- Reinsert the battery and test by entering the default code (1234).

5. Ensure Siren is in Operating Mode: If the Siren is in Service Mode, switch it to Operating Mode.

6. Check Radio Range: Ensure the keypad is within the effective range of the Siren and not near metal objects that may interfere with the signal.

If the keypad still does not work after these steps, additional troubleshooting may be required.

This answer is automatically generated

Akhtar khalil
March 18, 2025

MY SL2 alarms keypad is not working I need to help someone to come up and fix it

1 comments:
Mr. Anderson
March 18, 2025

To fix a keypad issue on your Response SL2 alarm system, follow these steps:

1. Check the Battery: If the “LOW BATT” LED is flashing, replace the PP3 Alkaline battery.
2. Ensure Proper Mounting: The keypad should be installed in a protected area near the main entrance, avoiding metal objects that might interfere with the signal.
3. Reinstall the Keypad:
- Undo and remove the fixing screw from the bottom edge.
- Remove the wall mounting plate.
- If needed, remove and reinstall the rear battery cover.
4. Reset the Keypad:
- If the battery was already installed, remove it.
- Press and hold any key for more than 1 second.
- Set the jumper link J1 as required.
5. Ensure Proper Communication with the Siren:
- If adding a new keypad, put the Siren in Service Mode.
- Program the keypad’s ID code into the Siren following the programming steps.
6. Verify Solar Siren Power: If using a solar siren, ensure it has received sufficient light to charge its battery before arming the system.

If the issue persists, recheck the installation and configuration steps.

This answer is automatically generated

ROMAN STEPHEN STUS
April 15, 2025

how to put alarm into test mode

1 comments:
Mr. Anderson
April 15, 2025

To put the Response SL2 alarm into test mode:

1. Ensure the siren is in Service Mode. If it is not, press and hold the button on the siren for 5 seconds until it emits one long beep followed by two short beeps. The LEDs will flash in sync with the beeps.
2. The siren automatically starts in Service Mode when first powered up.
3. The system should be tested regularly (at least every 3 months).
4. To stop the alarm and disarm the system after testing, enter your User Access Code followed by the ‘DISARM’ button on the Keypad.