Mounting Procedure Of Ksu; Figure 2-5 Wall-Mounting Template - NEC SL1100 Hardware Manual

Communication system
Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

ISSUE 1.0
Minimum 200 mm (7.874")
Minimum
300 mm
(11.811")
Minimum 200 mm (7.874")
Due to the limit of extension cable length to connect between Main KSU and Expansion KSU(s), the install
location of Main KSU and each Expansion KSU(s) must be considered as
of KSUs on this
page.

1.3.3 Mounting Procedure of KSU

One Main KSU or Expansion KSU(s) can be mounted per IP4WW-Battery Box. For the mounting, refer to
Mounting one KSU on the Battery Box on page
1. Place the attached template on the wall to mark the four screw positions.
2. Install four screws into the wall. The screw heads must stand off from the wall about 2.5 mm
(0.098") to 3.5 mm (0.138").
Hardware Manual
Ceiling
for ventilation
Minimum
100 mm
(3.937")
Main KSU
EXP. KSU
for ventilation
Floor
Figure 2-4 Horizontal Arrangement of KSUs
2-30.

Figure 2-5 Wall-Mounting Template

Minimum
Minimum
100 mm
300 mm
(3.937")
(11.811")
EXP. KSU
Figure 2-4 Horizontal Arrangement
Template
SL1100
Wall
2-5