General Purpose/Door Unlock Relay Specifications; External Paging Output Specifications; Bgm/Exmoh Source Input Specifications; External Sensor Device Interface Specifications - NEC SL1100 Hardware Manual

Communication system
Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

SL1100

2.12 General Purpose/Door Unlock Relay Specifications

Table 5-10 General Purpose/Door Unlock Relay Specifications

Item
Rated Voltage
Rated Current
Contact

2.13 External Paging Output Specifications

Item
Output Impedance
Output Level
Maximum Output

2.14 BGM/ExMOH Source Input Specifications

Table 5-12 BGM/External MOH Source Input Specifications

Item
Output Impedance
Input Level
Maximum Input

2.15 External Sensor Device Interface Specifications

Table 5-13 External Sensor Device Interface Specifications

Applied Voltage during
Sensor Off
24 V
5 V
The External Sensor device configuration shall be assigned by system program and the programming
is different with a Sensor Type.

2.16 CPU Card LAN Port Specifications

Item
Standard
Access
I/F (Layer 1)
5-6
DC 48 V Maximum
DC 320 mA Maximum
Normally Open

Table 5-11 External Paging Output Specifications

600
@ 1 kHz
Nominal 250 mV (-10 dBm)
400 mV RMS
600
@ 1 kHz
Nominal 250 mV (-10 dBm)
1 V RMS
Loop Current during Sensor
On
40 mA

Table 5-14 CPU Card LAN Port Specifications

IEEE802.3 10Base-T and 100Base-TX Compliant
CSMA/CD
Speed: 10 Mbps/100 Mbps Auto Negotiation
Cable: CAT5 or better, Straight/Cross Auto Crossover
Specification
Specification
Specification
Port Assignment
Program10-03-05: 0
Program10-03-05: 1
Specification
ISSUE 1.0
Specifications

Hide quick links: