2.3.3

IP-GW4 Card

Function
4-channel VoIP gateway card. Compliant with VoIP H.323 V.2 protocol, and ITU-T G.729a,
G.723.1, and G.711 CODEC methods.
To private IP network
Accessory and User-supplied Items
Accessory (included): Extension Bolt × 1, Strap × 1
User-supplied (not included): RJ45 connector
Notes
Maximum length of the cable to be connected to this optional service card is 100 m
(328 ft).
For programming instructions and other information about the IP-GW4 card, refer to
the documentation for the IP-GW4 card.
To confirm the CO line connection, refer to "Confirming the CO Line Connection" in
"2.11.1 Starting the Hybrid IP-PBX".
Pin Assignments
RJ45 Connector (10BASE-T/100BASE-TX)
TPO+
TPO-
1
RJ45
LEDs
Signal Name Input (I)/Output (O) Function
TPO+
TPI+
TPO-
TPI-
TPI+
8
TPI-
2.3 Installation of the CO Line Cards
O
Transmit data+
O
Transmit data-
I
Receive data+
I
Receive data-
Reserved