Applicable to KFR-25GWZ/BM KFR-35GWZ/BM KFR-50GWZ/BM KFR-70GWZ/BM Split Type Wall-mounted Inverter Room Air Conditioner Instruction Manual Thank you for purchasing a Shinco air conditioner.To guarantee safety and best efficiency, please read this manual carefully and keep it for future reference.
To Consumers 1. This air conditioning unit should be installed and repaired by a qualified technician. 2. The air conditioning unit must be grounded reliably during the installation. 3. Please clean the air filter nets 1 to 2 times per month when the air conditioner is being used frequently (details inside).
SAFETY PRECAUTIONS Please read the carefully before operating the SAFETY AND OPERATING INSTRUCTIONS unit. Please respect the following safety precautions when using your air conditioner to preventfire, shock hazard or personal injury. WARNING This sign warns of risk of death or serious injury. CAUTION This sign warns of injury or damage to property.
OPERATION PRECAUTIONS Do not operate with wet hands. Avoid staying directly in front of operating unit. Do not insert foreign objects into the unit. Always have the unit repaired by a professional technician - contact a service center. WARNING Danger of electric shock or fire if used improperly. Do not use if the power cord is damaged, it could cause an electric shock or fire.
T I M E SET TIMER Attention: The clock can be set even if the unit is closed. 3-2 Wind Speed-Wind Direction Adjustment For your comfort, adjust the wind speed and direction correctly. To adjust the wind speed, press on SPEED (see below): Medium High Auto...
To cancel time setting press the TIMER button. Nothing will be displayed on the LCD screen. One hour setting Press the 1HR button, the one hour setting function is on (the unit stops after running for 1 hour). To cancel press the 1HR button again. Note: the values used to display time are from 00:00 to 23:59.
Attention: 1. Select the cooling, heating or dehumidify mode according to the room temperature. If the quantity of clothes to dry is too large or the dehumidify mode is not activated, then the drying will not be completed. 3-7 Auto running Choose temperature, wind speed and direction automatically.
In heating mode: one hour after activating the SLEEP mode the preset temperature increases by 2 degrees automatically, and two hours after the preset temperature increases by another 2 degrees automatically again. This function will assure your comfort thru the night. Press SLEEP button again to cancel the sleep function.
Clean the air filter (once every two weeks) 2. Use vacuum cleaner or 3. To put the filters back into Hold the two ends of the water to clean the filters place hold the two ends of grill and gently push the and then dry.
6. Trouble Shooting Before calling a repair man, please check the followings: Symptom Possible reason • Problem with the remote control. • Problem with the voltage. Please shut the power, The air conditioner wait 3 minutes and restart the unit. does not work •...
Part Installation Instruction To guarantee the unit it must be installed according to the instructions in this manual. • The air conditioner has to be grounded properly. • Check the connecting cables and pipes carefully, make sure they are correct and firm before connecting the power of the air conditioner.
• The unit has to be more than 1 metre away from a fluorescent lamp or other electric bulbs ( they could interfere with the remote control). 1-2 Outdoor unit • It should be installed in a well ventilated place that is protected from strong winds.
2-2 Drill a hole in the wall • Select the location. • Drill a hole of approximately 6.5 cm diameter Insert the wall-through sheath into the hole Hole thru wall Wall-throughSheath Indoor Thickness of wall 2-3 Installation of the Power Source We recommend that you do not use an extension cord or an adapter plug with this appliance.
2-5 Arrangement of Pipes The drain hose must be put below the copper pipe. Put to- gether the refrigerant pipe, drain hose and the connecting wire of indoor and outdoor units. Wrap them with binding belt. The Front pipes can be arranged towards five directions (back, right, left, Right Back down and left-back).
3. Installation of Outdoor Unit The outdoor unit should be installed on a solid base. (Such as concrete) If it is in- stalled against a brick wall, the thickness of the brick wall should be at least 10cm deep. If there is a vibration, please install the protective anti-vibration rubber spacer. Do not install the unit directly on the ground;...
1. pipe cutting 4. Flare work Use pipe cutter to cut the copper Use the follow instruments to undertake pipe correctly flare work. qualified Unqualified A(mm) External diameter(mm) Copper pipe 90 Burr tilted rugged 0.8~1.5 1.2~1.8 1.2~2.0 1.5~2.5 yoke die 2.remove burrs Get rid all the burrs of the pipes Flare instrumen...
Page 21
Do not raise the Incline Drainage retention drain hose downward The distance between the The end of the hose end and the ground is drain hose is less than 5cm dipped into water Wave Dripping Dripping Dripping If the drain hose installed on the indoor unit is not long enough, please connect as shown on the dia- gram to your right.
3-5 Installation of the exterior draining pipe Insert the drainage pipe into the hole of the base, connect an extending pipe to drain the water. Base hole of the outdoor unit catchment trough 4. Test Run 4-1 Pipe-cleaning and vacuum verification Make sure all the pipe joints have been screwed tightly, then clean the pipes and verify the vacuum.
Remark Check the following items according to the related contents of this manual. Indoor unit : Is the noise abnormal? Does every indicating lamp function normally? Does it drain smoothly? Outdoor unit: Is there abnormal noise or vibration when it is running? Does the noise and water drainage disturb the neighbours? Is there a gas leak? The remote control:...