Indication
Level
S
XY feed forward / back speed
(Setting possible in the unit of 10pps)
S
When the power supply is turned on, 0: Normal
oautomatic preparation is possible 1: Automatic preparation is
without pressing the READY key.
S
While the needle stays in an upper 0: Holding disabled
position, a current is maintained in 1: Holding enabled
the main motor to make the needle
hard to down.
U
Method of XY enlargement/reduction 0: % setting
scale rate setting (IP200 only)
U
The origin is moved toward the
front by 5mm.
S
No. of pulses for work clamp foot
interlock wiper operation
S
The head falling detector switch
can be disabled.
U
This function sets whether or not
the calling of the pattern data is
operative.
S
Initialization of model's specifications 0:LK1900ASS
is executed.
U
Grease-up error
U
Pattern registration is carried out.
U
Cycle sewing registration is carried out.
S
Test mode is assumed.
Functions
100~4000pps
operated when the power
supply is ON.
1: Size setting
0: Standard
1: 5mm closer to the front
30~60
0: Normal
1: Head falling detector switch
disabled
0: Calling inoperative
1: Calling operative
1:LK1900AHS
2:LK1900AFS
3:LK1900AMS
4:LK1901ASS
5:LK1902ASS
6:LK1902AHS
7:LK1903ASS-301
8:LK1903ASS-302
9:LK1903ASS-311/BR35
10:LK1903ASS-312/BR35
11:LK1900AWS
The number of stitches is
counted based on drive,
sewing machine.
– 56 –
State when
Setting range
delivered
500
0
0
0
0
45
0
Setting dep- Standard pattern Nos. 1 to 64
ends on the can be individually set
model used. (Standard operation panel)
Setting
values are are initialized to the state when
specified
at left
according pattern is initialized to the state
to models. when delivered.
Remarks
Displayed only for the IP200
operation panel.
This setting is needed when
using the LK1904 presser foot
and patterns.
Contents of the memory switches
delivered.
The thread tension of each standard
All the registrations patterns
and cycles are deleted.
Only clearing possible with the
RESET key.
Clearing should be done after
the completion of grease-up action.
Need help?
Do you have a question about the LK-1900A Series and is the answer not in the manual?