Corinex CXP-HD200-WMEFe User Manual

Corinex CXP-HD200-WMEFe User Manual

Hd200 powerline wall mount f adapter

Advertisement

2-240220-200
HD200 Powerline Wall Mount F Adapter
CXP-HD200-WMEFe
Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CXP-HD200-WMEFe and is the answer not in the manual?

Questions and answers

Summary of Contents for Corinex CXP-HD200-WMEFe

  • Page 1 2-240220-200 HD200 Powerline Wall Mount F Adapter CXP-HD200-WMEFe Manual...
  • Page 2 Corinex HD200 Powerline Wall Mount F Corinex Communications Corp. 1000-1090 West Pender Street Vancouver, BC, V6E 2N7 Canada EMC: 2004/108/EC LVD: 2006/95/EC R&TTE: 1999/5/EEC RoHS: 2002/95/EC WEEE: 2002/96/EC EN 55022: 2006 (Class B) EN 55024: 1998 + AD1: 2001 + AD2: 2003...
  • Page 3 The content of this document is furnished for informational use only, it is subject to change without notice, and it does not represent a commitment on the part of Corinex Communications Corp.
  • Page 4: End User License Agreement

    5. Limitation of Liability. Corinex’s entire liability and your exclusive remedy under this EULA shall not exceed the price paid for the Software, if any. In no event shall CORINEX or its suppliers be liable to you for any consequential, special, incidental or indirect damages of any kind arising out of the use or inability to use the software, even if CORINEX or its supplier has been advised of the possibility of such damages, or any claim by a third party.
  • Page 5 8. Precedence. Except as set out above, where separate terms are provided by the software supplier, then, subject to this EULA, those terms also apply and prevail, to the extent of any inconsistency with this EULA. Corinex HD200 Powerline Wall Mount F...
  • Page 6: Table Of Contents

    Configuring the DHCP / TFTP Server Providing an IP Address Writing an Auto-configuration File Device specific parameters 8.1 Enable/disable multicast aging 8.2 Enable/disable interface EXTA 8.3 Show all MAC addresses for interface EXTA 8.4 Node number Troubleshooting Guide Corinex HD200 Powerline Wall Mount F...
  • Page 7: Introduction

    Introduction 1.1 Overview The Corinex HD200 Powerline Wall Mount F is a network interface adapter which uses the electric power lines already in your home or office as a medium for communication. After successful installation, the HD200 Powerline network behaves like a traditional LAN for computers.
  • Page 8: Installation Guide

    Installation Guide Installation Guide 2.1 What this Package Contains When you receive your Corinex HD200 Powerline Wall Mount F, check to be sure that your package contains: • Corinex HD200 Powerline Wall Mount F (2 for dual pack) • Standard Ethernet cable (2 for dual pack) • CD with documentation...
  • Page 9: Device Description

    The ltered electrical outlet on top of the device makes the usage of the adapter easier, as other appliances can be plugged here in, so the Powerline Adapter does not block the wall outlet. Corinex HD200 Powerline Wall Mount F...
  • Page 10: Led Description

    Green flashes disabled in progress every 2 seconds Red/Green disabled finished in progress alternating Green flashes disabled finished finished in progress every 0.5 seconds Green disabled finished finished finished Corinex HD200 Powerline Wall Mount F...
  • Page 11 The adapter has no link on Ethernet interface. Green There is a 100 Mbps link on Ethernet interface. Amber There is a 10 Mbps link on Ethernet interface. Blinking (Green or There is activity on the Ethernet interface. Amber) Corinex HD200 Powerline Wall Mount F...
  • Page 12: Technical Speci Cations

    All Enterprise modems are set to run the auto-con guration process by default. This process uses DHCP and TFTP to obtain the network settings and modem con guration. It also uses a proprietary protocol called PTTP (Parametric Translation Table Protocol) to communicate with the management VLAN. Corinex HD200 Powerline Wall Mount F...
  • Page 13: Connecting The Hd200 Powerline Wall Mount F

    2. Plug the adapter directly into any standard electrical outlet. Note: The Powerline adapter should be plugged directly into a wall outlet, not into a power strip or surge suppressor. Power strips and surge suppressors can weaken or block the Powerline network signal. Corinex HD200 Powerline Wall Mount F...
  • Page 14: Starting Up The Modem

    If you cannot see the DHCP packets coming from the modem, the possible causes include: • The firewall is filtering out these packets • You are not running Wireshark on the physical Ethernet interface • The adapter does not have the factory-default configuration • The adapter is booting in NVRAM mode and is set with static IP settings. Note: In order to see the DHCP discovery, Factory reset is suggested. Corinex HD200 Powerline Wall Mount F...
  • Page 15: Topology With Hd200 Enterprise Device

    The HD200 Powerline Wall Mount F can be used only as a slave (CPE, Customer Premises Equipment). In order to create a simple network, another adapter from Corinex’s portfolio (such as Low Voltage Gateway, High Density Gateway or High Density Building Controller) has to be used as master device.
  • Page 16: Configuring The Dhcp / Tftp Server

    You must then specify this directory in the DHCP application, under Options > Preferences. On the “Interfaces” tab, check the option “Respond to registered (static) addresses/identifiers only”. Please pay attention to selection of interfaces. Figure 3: Interfaces tab settings Corinex HD200 Powerline Wall Mount F...
  • Page 17 “Add”. A new window will pop up (see figure on next page). 3. In the tab, “Basic Profile”, set a subnet mask that is compatible with your computer settings. Under gateway, enter the static IP of your computer or leave it blank. Corinex HD200 Powerline Wall Mount F...
  • Page 18 4. In the tab, “Boot”, type the IP address of your computer under “Next Server IP Address” and “Name”. Then check the option, “Always use option 66/67 for Name and File”. Figure 6: Boot tab Corinex HD200 Powerline Wall Mount F...
  • Page 19 In this window, you must enter the MAC address of the modem, the IP address that you want assigned to this modem, and the configuration profile. When you click OK, it will create an entry in the static leases list. Corinex HD200 Powerline Wall Mount F...
  • Page 20 If none of the Slaves gets an IP, the probable cause is that the Master was not properly configured. If the Master modem does not become Master, the Slaves will not be able to find a network signal to link to. Corinex HD200 Powerline Wall Mount F...
  • Page 21 Configuring the DHCP / TFTP Server Figure 9: Static leases list, showing date and time of a recently configured node Corinex HD200 Powerline Wall Mount F...
  • Page 22: Providing An Ip Address

    The option 120 is used to disable PTTP in the DHCP response. This will prevent the modem from trying to obtain the management VLAN from another Powerline modem. In some cases, the PTTP has been known to interfere with Windows XP network services. Corinex HD200 Powerline Wall Mount F...
  • Page 23 DHCP acknowledgement. Discovery and request are issued by the modem, while offer and acknowledgement are issued by the client computer. Once the modem has an IP address, you should be able to ping it. Corinex HD200 Powerline Wall Mount F...
  • Page 24: Writing An Auto-Configuration File

    Note: The HD200 Powerline Wall Mount F can be used only as a slave (CPE, Customer Premises Equipment). In order to create a simple network as described above, another adapter from Corinex’s portfolio has to be used as master device.
  • Page 25: Device Specific Parameters

    Device specific parameters This chapter describes autoconfiguration parameters and MIBs, that are specific for the Corinex HD200 Powerline Wall Mount F. The general parameters can be found in the remaining two documents: Alma auto-configuration and SNMP manual. 8.1 Enable/disable multicast aging A new functionality was added in the firmware to enable/disable multicast aging.
  • Page 26: Show All Mac Addresses For Interface Exta

    The parameter NODE_NUMBER has to be placed before the parameter GENERAL_ TYPE. A valid value for the parameter is 1 ~ 99. Factory default value is 0. Corinex HD200 Powerline Wall Mount F...
  • Page 27: Troubleshooting Guide

    Troubleshooting Guide Troubleshooting Guide The Corinex HD200 Powerline Wall Mount F has been designed to be a reliable and easy-to-use network connection device. Please refer to the list below to aid in troubleshooting. The AP LED is off. 1. Make sure the power adapter is properly plugged directly into the electrical outlet, and that the outlet has power.
  • Page 28 • If it’s possible, send us a scheme of your network topology also with the IP addresses for computers/router/access point, this can speed up the problem estimation. If you use any non-Corinex equipment, please specify what kind. The drawing can be made in any graphics editor, exported to one of the standard graphic formats (JPEG, GIF).

This manual is also suitable for:

Hd200

Table of Contents