Beta Marine BV1903 Operator's Maintenance Manual page 50

Heat exchanger cooled mid diesel engine range 43 and 50 bhp
Table of Contents

Advertisement

BETA CONTROLLER
SEA SPEC ENGINES
The BETA CONTROLLER
is an integrated battery ch
arging external regulator. It
is designed to be used
with Beta
s 70 and 100am
p Iskra alternators.
The system utilises a three
stage charging characteristic which optimises the rapid
charge of battery systems.
The first stage (A mode) is a boost charge, which is indicated by the indicator LED
showing red.
The second stage (B mode) is where the voltage is kept at a high level and where
the current is between 10% and 95% of the nominal alternator current, the LED
shows orange.
The third and last stage (C mode) is intended for maintenance of battery voltage
only. When the alternator current is under a predetermined value for a time greater
than 2 minutes, the regulating mode is changed from B to C mode.
The system automatically adjusts the charge mode to suit the load and is set in our
works for conventional lead-acid batteries. It can easily be re-set for deep cycle or
gel batteries. A more detailed specification can be obtained from BETA MARINE.
A.MODE
B.MODE
C.MODE
RED L.E.D
ORANGE L.E.D
GREEN L.E.D
AMPS
VOLTS
TIME
INSTALLATION
The Beta Controller has been designed
for mounting off the engine in a location
away
from
vibration,
water
and
condensation.
Ideally as there is a
charge mode status LED, the unit should
be positioned to allow for inspection of
charge operating condition.