Troubleshooting; Trouble Display Table - Sanyo SHP-TH90GDN-SW Technical Manual

Natural refrigerant heat pump water heater, tank unit, heat pump unit
Table of Contents

Advertisement

Trouble display table

First check the details of the trouble display, and then be absolutely sure to turn off
the power.
<Tank unit>
Display
SENSOR
Primary flow sensor trouble
PRIMARY FLOW
SENSOR
Tank temperature sensor trouble
TANK TEMP
SENSOR ROOM
Room sensor trouble
SENSOR EL UP
Electric heater Sensor trouble
SENSOR EL LO
SENSOR OUT
Outdoor sensor trouble
COMM ERROR
Serial communication error
Trouble
Open-circuit or short-circuit in sensor itself or lead wires
<Diagnosis>
• Defective contact of connector or defective crimping of
• Defective tank unit PCB
Serial communication error
<Diagnosis>
• Inadequate power supply due to incorrectly plugged in
• Defective in the current fuse in heat pump unit
• Defective PCB in tank unit or heat pump unit
Criteria and diagnosis
terminal
connector or Incorrectly wired power cable or
communication cable