Mitsubishi Electric FREQROL Connection Manual page 143

Inverter driver gp-pro ex device/plc connection manual

Advertisement

FR-A700/FR-A701 series, FR-F700 series, FR-B,B3(A700) series, FR-B,B3(A500) series
Word
FR-A700/FR-A701 series
Address
S00
Operation mode
S01
Output frequency/speed
S02
Output current
S03
Output voltage
S04
Special monitor
Special monitor selection
S05
No.
S06
Output frequency
S07
Output current
S08
Output voltage
S09
Frequency setting
S10
Running speed
S11
Motor torque
S12
Converter output voltage
S13
Regenerative brake duty
Electronic thermal relay
S14
function load factor
S15
Output current peak value
Converter output voltage
S16
peak value
S17
Input power
S18
Output power
S19
Input terminal status
S20
Output terminal status
S21
Load meter
S22
Motor excitation current
S23
Position pulse
Cumulative energization
S24
time
S25
Orientation status
S26
Actual operation time
S27
Motor load factor
S28
Cumulative power
S29
Torque command
S30
Torque current command
S31
Motor output
S32
Feedback pulse
S33
Power saving effect
S34
Cumulative saving power
S35
PID set point
S36
PID measured value
S37
PID deviation value
S38
Option input terminal status1
S39
Option input terminal status2
S40
Option output terminal status
S41
-
S42
-
Alarm definition
S43
(Latest Nos. 1&2)
Alarm definition
S44
(Latest Nos. 3&4)
GP-Pro EX Device/PLC Connection Manual
FR-F700 series
Operation mode
Output frequency/speed
Output current
Output voltage
Special monitor
Special monitor selection
No.
Output frequency
Output current
Output voltage
Frequency setting
Running speed
-
Converter output voltage
Regenerative brake duty
Electronic thermal relay
function load factor
Output current peak value
Converter output voltage
peak value
Input power
Output power
Input terminal status
Output terminal status
Load meter
-
-
Cumulative energization
time
-
Actual operation time
Motor load factor
Cumulative power
-
-
-
-
Power saving effect
Cumulative saving power
PID set point
PID measured value
PID deviation value
-
-
-
-
-
Alarm definition
(Latest Nos. 1&2)
Alarm definition
(Latest Nos. 3&4)
143
FR-B,B3(A700) series
Operation mode
Output frequency/speed
Output current
Output voltage
Special monitor
Special monitor selection
No.
Output frequency
Output current
Output voltage
Frequency setting
Running speed
Motor torque
Converter output voltage
Regenerative brake duty
Electronic thermal relay
function load factor
Output current peak value
Converter output voltage
peak value
Input power
Output power
Input terminal status
Output terminal status
Load meter
Motor excitation current
Position pulse
Cumulative energization
time
Orientation status
Actual operation time
Motor load factor
Cumulative power
-
-
Motor output
-
Power saving effect
Cumulative saving power
PID set point
PID measured value
PID deviation value
Option input terminal status1
Option input terminal status2
Option output terminal status
-
-
Alarm definition
(Latest Nos. 1&2)
Alarm definition
(Latest Nos. 3&4)
FREQROL Inverter Driver
FR-B,B3(A500) series
Operation mode
Output frequency[speed]
Output current
Output voltage
Special monitor
Special monitor selection
No.
Output frequency
Output current
Output voltage
Frequency setting
Running speed
Motor torque
-
Regenerative brake
Electronic overcurrent
protection load factor
Output current peak value
Converter output voltage
peak value
Input power
Output power
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Alarm definition
(Latest Nos. 1&2)
Alarm definition
(Latest Nos. 3&4)