OPERATION
CONTROL PANEL FAULT INDICATOR CODES
The control panel fault indicator lights will display the following codes when the machine detects a fault.
CODE
Light #1 blinks
Lights #1, #2 and #3
ripple
Lights #1 and #4 blink
Lights #3 and #4 blink
Lights #2 and #3 blink
Lights #1 and #3 blink
Light #2 blinks
Lights #1 and #2 blink
Light #3 blinks
Light #3 blinks when
pressing the solution flow,
brush pressure buttons
and FaST system switch
Lights #1, #2 and #3 blink
All battery lights blink
All battery lights ripple
34
Light #4
Light #1
Light #2
FAULT
Recovery tank is raised.
Battery charger connected.
Left Brush motor overload.
Right Brush motor overload.
Propel motor overload.
Exceeded maximum incline.
Scrub head movement is obstructed or
actuator motor malfunction.
Vacuum motor malfunction.
Propel throttle malfunction.
FaST pump overload or malfunction.
Supervisor controls activated
(lockout feature)
Wand Pump overload or malfunction.
Emergency--Stop button activated
Key turned on while bail was engaged.
Light #3
Battery Lights
SOLUTION
Lower recovery tank. Restart key to reset.
Disconnect battery charger. Restart key to
reset.
Inspect brush for entangled debris,
improper pad or contact service center.
Restart key to reset.
Inspect brush for entangled debris,
improper pad or contact service center.
Restart key to reset.
Avoid steep inclines or contact service
center. Restart key to reset.
Check scrub head for obstruction or con-
tact service center. Restart key to reset.
Contact service center.
Contact service center.
Reset the 10A circuit breaker or contact
service center. Restart key to reset.
Contact your Supervisor.
Reset the 10A circuit breaker button or
contact service center. Restart key to
reset.
Turn button clockwise to reset.
Release the control handle start bail.
Tennant T5 (06- -06)
Need help?
Do you have a question about the T5 and is the answer not in the manual?
Questions and answers
Not lowering the pad
The Tennant T5 may not be lowering the pad due to the Recovery Tank Interlock. If the Recovery Tank is raised, the interlock switch remains open, preventing the machine from operating correctly. This would cause Fault LED #1 to flash. Ensure the Recovery Tank is properly seated to allow normal operation.
This answer is automatically generated
Tenant t5 flashing light 1,2,3 . Machine have not FaST
Flashing lights on the Tennant T5 machine without FaST indicate the following:
- Fault LED #1 flashing: Excessive left brush current (>35A for 2 seconds) or disk head motor current (>30A for 1 minute). This turns off all scrub functions.
- Fault LED #2 flashing: Excessive vacuum fan current (>27A for 30 seconds). This turns off all scrub functions.
- Fault LED #3 flashing: Excessive right brush current (>35A for 2 seconds) or disk head motor current (>30A for 1 minute). This turns off all scrub functions.