ZXR10 Alarm Handling Manual
Cause
Influence
Recommended
Operations
Alarm Description
Prototype
Alarm Description
Supported Devices
Message No.
Default Security
Level
Alarm Type
NM Level
Cause
Influence
Related Alarms
Recommended
Operations
Alarm Description
Prototype
Alarm Description
Supported Devices
Message No.
Default Security
Level
Alarm Type
140
Confidential and Proprietary Information of ZTE CORPORATION
OAM link is disconnected.
OAM link is disconnected and can't connect ONU.
Check OAM link state, disconnect and re-connect ONU, or reboot
the entire rack.
This alarm is called oam link disconnection alarm in EPON project.
In default, this alarm is enabled. If the alarm need to be disabled
configure "alarm oam-link-disconnection disable" on OLT interface.
"Epon alarm oam-link-disconnection occour!"
Example:
18:41:30 08/26/2008 UTC alarm 33287 occurred %EPON% Epon
alarm oam-link-disconnection occour! sent by NPC 3
OAM link is disconnected.
EPON project of 4822
33288
33288
5
"CommunicationAlarm"
4
Data loading fault or other dying gasp fault.
The optical path is abnormal.
33290
Disconnect and re-connect the connection between ONU and OLT.
Register ONU again.
This alarm is called dying gasp alarm in EPON project. In default,
this alarm is enabled. If the alarm need to be disabled configure
"alarm dying-gasp disable" on OLT interface.
"Epon alarm dying-gasp occour!"
Example:
14:57:30 08/26/2008 UTC alarm 33288 occurred %EPON% Epon
alarm dying-gasp occour! sent by NPC 3
Communication over fiber is abnormal.
EPON project of 4822
33289
33289
5
"CommunicationAlarm"