Error code
Problem
3C50-3C52
Offramp transmission
error
3C60-3C62
Offramp security error
3C70
Power failure
3D10
Destination address
error
3D20
Exceeding maximum
offramp destinations
3D30
Fax unit is not installed Make sure the Fax unit is installed, or connected correctly.
3E10
POP3 server commu-
nication error
3E20
POP3 server commu-
nication timeout
3E30
POP3 login error
3E40
POP3 login type error
3F00, 3F10,
File I/O error
3F20, 3F30,
3F40
Ask the sender to specify the correct fax numbers and resend
the E-mail.
Confirm the fax numbers that are specified in the received
offramp gateway job and ask the sender to resend the E-mail
with correct fax numbers.
Confirm the job is recovered or not. If not, ask the sender to
resend the E-mail.
Ask your administrator whether the DNS and mail server set-
tings are correctly set. If they are correctly set, ask the sender to
confirm the destination address is correct.
Ask the sender to specify up to 40 destinations for one offramp
gateway job. The equipment cannot perform the offramp gate-
way transmission for more than 40 destinations.
Ask your administrator that the POP3 server address is cor-
rectly set, or the POP3 server works properly.
Check if the SSL setting and the port number of SSL corre-
spond to those of the SSL server.
Ask your administrator that the POP3 server works properly and
the LAN cable is connected to the server.
Ask your administrator that the POP3 user name and password
is set correctly.
Ask your administrator if the login types (Auto, POP3, APOP) to
the POP3 server are correct.
Ask the sender to resend the E-mail. If the error still occurs,
contact your service representative.