Replacement Procedure
(8) How to Remove A Massage Unit
1, Remove four cover(back cover) set screws
and take off a cover(back cover).
Cover(back cover)
set screws
2, Move the massage unit upwards to its top position.
Usually the massage unit is at a stop at its top
position. When the massage unit is at a stop
halfway, however, turn on the power and make
the massage unit move up to its top position.
At the top position, when the massage unit
comes to a stop, pull out a POWER plug.
Moving
upwards
Pulley (elevation)
Connector (main)
* While the massage unit is moving upwards,
exercise care so as not to come into contact
with the operating portion.
Photo-16
Cover(back cover)
Photo-16
Photo-17
Massage unit
Spring A(main harness )
POWER switch
Photo-17
- 25 -
If the massage unit does not move upwards
when the power is turned on, turn a pulley
(elevation) clockwise to move the massage unit
to the top position.
3, Remove the cord processing of the cord (main)
and disconnect the connectors (four connectors
for motors, one for signal line).
Remove one earthing set screw and cut eight
insulation lock black cords.
* Cut the cords with a nipper so that the cords
do not get scratched.
* In order to restore the wiring processing after
reassembling the massage unit, indicate a
markon the cords before disconnecting the
wiring.
4, Remove one spring A (harness main) set
screw and take off a spring A (harness main).
5, Remove two screws(stopper) inside of a
back frame.
6, Turn the pulley (massage) clockwise to
minimize the massage hand width.
7, Turn the pulley (strength) counterclockwise
to bring to minimum position (maximum
strength) of a thread bar.
Screw (stopper)
Pulley (massage)
Connector ass'y (main)
HEC-DR5000
(GENERAL)
Photo-17
Photo-18
Photo-18
Photo-18
Photo-18
Photo-18
Pulley (strength)
Spring A(main harness )
Photo-18