Download Print this page

Sanyo HEC-DR5000 Service Manual page 23

Chair type massager
Hide thumbs Also See for HEC-DR5000:

Advertisement

Replacement Procedure
(4) Replacement of Reclining Motor
1, Take off the arm rest (left).
2, Take off the arm rest (right).
3, Disconnect each cord processing and cords.
4, Lay down the massager with its left side
facing downward.
5, Each reclining motor (set) is fixed at two
places on both ends. Therefore, remove
E rings on both ends and pull out fixing pins.
Reclining motor (back rest)
Reclining motor (back rest)
E rings & fixing pins
Photo-1
Photo-5
Photo-8
Photo-8
Photo-9
E rings & fixing pins
Reclining motor (foot rest)
Reclining motor (foot rest)
Photo-9
(5) Replacement of Power Switch
and Current Fuse
1, Take off the arm rest (right).
2, Remove each cord processing and
disconnect the cords.
3, Remove two case (switch box) set screws
and take off the case (switch box).
Case (switch box)
Case set screws
4, Open a fuse case of current fuses and take
out a current fuse.
5, Remove two switch holder set screws and
take off a switch holder.
6, Remove a switch fixing screw and take off
the POWER switch.
POWER switch
Power cord
- 23 -
HEC-DR5000
(GENERAL)
Photo-5
Photo-10
Connector (sensor)
Connector (remote control)
Photo-10
Photo-11
Photo-11
Photo-11
Switch holder set screws
Current fuse
Photo-11

Advertisement

loading